TF016 ZWave Thermostat

This describes the Z-Wave device TF016, manufactured by ThermoFloor with the thing type UID of thermofloor_tf016_00_000. This version of the device is limited to firmware versions below 1.7

The device is in the category of HVAC, defining Air condition devices, Fans.

TF016 product image

The TF016 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.

Overview

The Heatit Z-Wave is an electronic thermostat for floor heating in a standard wall box. The thermostat has a built-in Z-Wave chip that can be connected with Home Automation systems.

Heatit Z-Wave is equipped with a single pole switch and fits into most System 55 frames (Elko RS16, Schneider Exxact, Gira, Jung etc.) The thermostat can withstand a load of max 16A / 3600W at 230V. At higher loads the thermostat must control a contactor. The thermostat may be connected to two wired external sensors.

The thermostat has the capacity of up to 8 associations (relays, wall plugs etc.)

The thermostat is designed for electrical heating.

Inclusion Information

To include the thermostat to your home automation gateway, press Center (confirm) for 10 seconds. The display will show OFF. Press Right (down) 4 times till you see Con in the display. Now start add device in your home automation software. Start inclusion mode by pressing Center (confirm) for approximately 2 seconds. The inclusion/exclusion icon will appear in the display. Confirmation will show Inc/EcL in the display. If inclusion fails, Err (error) will appear. Leave programming mode by choosing ESC in menu. Your thermostat is ready for use with default settings

Exclusion Information

See information for inclusion.

Channels

The following table summarises the channels available for the TF016 -:

Channel Channel Id Category Item Type
Sensor (temperature) sensor_temperature Temperature Number
Electric meter (kWh) meter_kwh Energy Number
Thermostat mode thermostat_mode Temperature Number
Setpoint (heating) thermostat_setpoint Temperature Number
Setpoint (furnace) thermostat_setpoint Temperature Number
Setpoint (economy) thermostat_setpoint Temperature Number

Sensor (temperature)

Indicates the current temperature.

The sensor_temperature channel supports the Number item and is in the Temperature category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Thermostat mode

Sets the thermostat.

The thermostat_mode channel supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Off
1 Heat
2 Cool
3 Auto
4 Aux Heat
5 Resume
6 Fan Only
7 Furnace
8 Dry Air
9 Moist Air
10 Auto Changeover
11 Heat Economy
12 Cool Economy
13 Away
15 Full Power
31 Manufacturer Specific

Setpoint (heating)

Sets the thermostate setpoint.

The thermostat_setpoint channel supports the Number item and is in the Temperature category.

Setpoint (furnace)

Sets the thermostate setpoint.

The thermostat_setpoint channel supports the Number item and is in the Temperature category.

Setpoint (economy)

Sets the thermostate setpoint.

The thermostat_setpoint channel supports the Number item and is in the Temperature category.

Device Configuration

The following table provides a summary of the 1 configuration parameters available in the TF016. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Operation mode Defines Operation Mode of thermostat

Parameter 1: Operation mode

Defines Operation Mode of thermostat 0….OFF(0x00)

1…..HEAT (0x01)

2…..COOL (0x02)

11….ENERGY SAVE HEAT (0x0B)

Default value 1 The following option values may be configured -:

Value Description
0 OFF
1 Heat
2 Cool
11 Energy Save Heat

The manufacturer defined default value is 1 (Heat).

This parameter has the configuration ID config_1_2 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The TF016 supports 2 association groups.

Group 1: Lifeline

This group supports 8 nodes.

Group 2: On/Off control

This group supports 8 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1  
COMMAND_CLASS_BASIC_V1  
COMMAND_CLASS_SENSOR_MULTILEVEL_V6  
COMMAND_CLASS_METER_V3  
COMMAND_CLASS_THERMOSTAT_MODE_V1  
COMMAND_CLASS_THERMOSTAT_SETPOINT_V1  
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1  
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1  
COMMAND_CLASS_ZWAVEPLUS_INFO_V1  
COMMAND_CLASS_CONFIGURATION_V1  
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1  
COMMAND_CLASS_POWERLEVEL_V1  
COMMAND_CLASS_ASSOCIATION_V1  
COMMAND_CLASS_VERSION_V1  