TF016 ZWave Thermostat

This describes the Z-Wave device TF016, manufactured by ThermoFloor with the thing type UID of thermofloor_tf016_00_000.

ZWave Thermostat

Channels

The following table summarises the channels available for the TF016 ZWave Thermostat.

Channel Channel Id Channel Type UID Category Item Type
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Thermostat mode thermostat_mode thermofloor_tf016_00_000_thermostat_mode Temperature Number
Setpoint (heating) thermostat_setpoint_heating thermostat_setpoint Temperature Number
Setpoint (furnace) thermostat_setpoint_furnace thermostat_setpoint Temperature Number
Setpoint (economy) thermostat_setpoint_heating_econ thermostat_setpoint Temperature Number

Sensor (temperature)

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Setpoint (heating)

Scale

Select the scale to use for setpoints.

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Setpoint (furnace)

Scale

Select the scale to use for setpoints.

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Setpoint (economy)

Scale

Select the scale to use for setpoints.

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Device Configuration

The following table provides a summary of the configuration parameters available in the TF016 ZWave Thermostat. Detailed information on each parameter can be found below.

Parameter Description
1: Operation mode Defines Operation Mode of thermostat
1: Lifeline  
2: On/Off control  

1: Operation mode

Defines Operation Mode of thermostat

Overview

0….OFF(0x00)

1…..HEAT (0x01)

2…..COOL (0x02)

11….ENERGY SAVE HEAT (0x0B)

Default value 1

Property Value      
Configuration ID config_1_2      
Data Type INTEGER   Default Value 1
Options OFF (0)      
  Heat (1)      
  Cool (2)      
  ENERGY SAVE HEAT (11)      

1: Lifeline

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: On/Off control

Property Value
Configuration ID group_2
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.