TZ79 Insert switch module

This describes the Z-Wave device TZ79, manufactured by TKB Home with the thing type UID of tkb_tz79_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

TZ79 product image

The TZ79 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.

Overview

Inclusion Information

  1. Have Z-Wave Controller entered inclusion mode.
  2. Pressing On/Off button three times within 1.5 secondes will enter inclusion mode.

Exclusion Information

  1. Have Z-Zwave controller entered exclusion mode.
  2. Pressing On/Off button three times within 1.5 secondes will enter exclusion mode.

Channels

The following table summarises the channels available for the TZ79 -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch
Electric meter (power factor) meter_powerfactor Energy Number
Electric meter (kWh) meter_kwh Energy Number
Electric meter (amps) meter_current Energy Number
Electric meter (volts) meter_voltage Energy Number
Electric meter (watts) meter_watts Energy Number

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Electric meter (power factor)

Indicates the instantaneous power factor.

The meter_powerfactor channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (amps)

Indicates the instantaneous current consumption.

The meter_current channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (volts)

Indicates the instantaneous voltage.

The meter_voltage channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Device Configuration

The following table provides a summary of the 7 configuration parameters available in the TZ79. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Change the state of indicator light  
2 Memory Function  
3 Watt Meter Report Period 5s x 720 (default) = 3600s = 1 hour
4 kWH Meter Report Period 6x10min = 1 hour
5 Threshold of Watt for load caution  
6 Threshold of kWH for load caution  
7 Edge or Pulse mode or Edge-Toggle mode 1 - Edge mode 2 - Pulse mode 3 - Edge toggle mode
  Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: Change the state of indicator light

The following option values may be configured -:

Value Description
0 LED off
1 LED on

The manufacturer defined default value is 1 (LED on).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Memory Function

The following option values may be configured -:

Value Description
0 Memory function off
1 Memory function on

The manufacturer defined default value is 1 (Memory function on).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Watt Meter Report Period

5s x 720 (default) = 3600s = 1 hour If the setting is configured for 1 hour (set value = 720), the TZ79 will report its instant power consumption every 1 hour to Z-Wave controller. The maximum interval to report its instant power consumption is 45 hours (5s*36767/3600 = 45 hours) Values in the range 1 to 32767 may be set.

The manufacturer defined default value is 720.

This parameter has the configuration ID config_3_2 and is of type INTEGER.

Parameter 4: kWH Meter Report Period

6x10min = 1 hour

Values in the range 1 to 32767 may be set.

The manufacturer defined default value is 6.

This parameter has the configuration ID config_4_2 and is of type INTEGER.

Parameter 5: Threshold of Watt for load caution

Values in the range 10 to 3000 may be set.

The manufacturer defined default value is 3000.

This parameter has the configuration ID config_5_2 and is of type INTEGER.

Parameter 6: Threshold of kWH for load caution

Values in the range 0 to 10000 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_6_2 and is of type INTEGER.

Parameter 7: Edge or Pulse mode or Edge-Toggle mode

1 - Edge mode 2 - Pulse mode 3 - Edge toggle mode

Values in the range 1 to 3 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -: | Value | Description | |——–|————-| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups |

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The TZ79 supports 1 association group.

Group 1: Lifeline

This group supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1  
COMMAND_CLASS_BASIC_V1  
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1  
COMMAND_CLASS_METER_V3  
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1  
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1  
COMMAND_CLASS_ZWAVEPLUS_INFO_V1  
COMMAND_CLASS_CONFIGURATION_V1  
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1  
COMMAND_CLASS_POWERLEVEL_V1  
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1  
COMMAND_CLASS_ASSOCIATION_V2  
COMMAND_CLASS_VERSION_V2  