TZ69 Smart meter switch

This describes the Z-Wave device TZ69, manufactured by TKB Home with the thing type UID of tkb_tz69_00_000.

Smart meter switch

Channels

The following table summarises the channels available for the TZ69 Smart meter switch.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (amps) meter_current meter_current Energy Number
Electric meter (power factor) meter_powerfactor meter_powerfactor Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (volts) meter_voltage meter_voltage Energy Number

Device Configuration

The following table provides a summary of the configuration parameters available in the TZ69 Smart meter switch. Detailed information on each parameter can be found below.

Parameter Description
1: LED Indicator Mode Sets whether LED should indicate device is on (1) or off (0)
2: Memory Function determines if current state is memorized on power failure
3: Watt Meter Report Period 5s x 720 (default) = 3600s = 1 hour
4: kWH Meter Report Period 10m * 6 (default) = 60m = 1 hour
5: Threshold of Watt for Load Caution Above this level, switch enters overload mode
6: Threshold of kWH for Load Caution Over this level, unit with go into overload mode
1: Lifeline  

1: LED Indicator Mode

Sets whether LED should indicate device is on (1) or off (0)

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 1
Options Switch off = LED off (0)      
  Switch off = LED on (1)      

2: Memory Function

determines if current state is memorized on power failure

Overview

Manual states: TZ69 by default value is 1, when the value is 0, TZ69 memory function not used; when the value is 1, TZ69 memory function is used

Property Value      
Configuration ID config_2_1      
Data Type INTEGER   Default Value 1
Options Memory function off (0)      
  Memory function on (1)      

3: Watt Meter Report Period

5s x 720 (default) = 3600s = 1 hour

Property Value
Configuration ID config_3_2
Data Type INTEGER
Range 1 to 32767
Default Value 720

4: kWH Meter Report Period

10m * 6 (default) = 60m = 1 hour

Property Value
Configuration ID config_4_2
Data Type INTEGER
Range 0 to 32767
Default Value 6

5: Threshold of Watt for Load Caution

Above this level, switch enters overload mode

Overview

Overload mode means the switch is disabled and the LED flashes at 0.5 second intervals. Unplug unit to clear mode.

Property Value
Configuration ID config_5_2
Data Type INTEGER
Range 10 to 3000
Default Value 3000

6: Threshold of kWH for Load Caution

Over this level, unit with go into overload mode

Overview

Overload mode means the switch is disabled and the LED flashes at 0.5 second intervals. Unplug unit to clear mode.

Property Value
Configuration ID config_6_2
Data Type INTEGER
Range 1 to 10000
Default Value 10000

1: Lifeline

Property Value
Configuration ID group_1
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.