TZ79 Insert switch module

This describes the Z-Wave device TZ79, manufactured by TKB Home with the thing type UID of tkb_tz79_00_000.

Insert switch module

Inclusion Information

  1. Have Z-Wave Controller entered inclusion mode.
  2. Pressing On/Off button three times within 1.5 secondes will enter inclusion mode.

Exclusion Information

  1. Have Z-Zwave controller entered exclusion mode.
  2. Pressing On/Off button three times within 1.5 secondes will enter exclusion mode.

Channels

The following table summarises the channels available for the TZ79 Insert switch module.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Electric meter (power factor) meter_powerfactor meter_powerfactor Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (amps) meter_current meter_current Energy Number
Electric meter (volts) meter_voltage meter_voltage Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number

Device Configuration

The following table provides a summary of the configuration parameters available in the TZ79 Insert switch module. Detailed information on each parameter can be found below.

Parameter Description
1: Change the state of indicator light  
2: Memory Function  
3: Watt Meter Report Period 5s x 720 (default) = 3600s = 1 hour
4: kWH Meter Report Period 6x10min = 1 hour
5: Threshold of Watt for load caution  
6: Threshold of kWH for load caution  
7: Edge or Pulse mode or Edge-Toggle mode 1 - Edge mode 2 - Pulse mode 3 - Edge toggle mode
1: Lifeline  

1: Change the state of indicator light

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 1
Options LED off (0)      
  LED on (1)      

2: Memory Function

Property Value      
Configuration ID config_2_1      
Data Type INTEGER   Default Value 1
Options Memory function off (0)      
  Memory function on (1)      

3: Watt Meter Report Period

5s x 720 (default) = 3600s = 1 hour

Overview

If the setting is configured for 1 hour (set value = 720), the TZ79 will report its instant power consumption every 1 hour to Z-Wave controller. The maximum interval to report its instant power consumption is 45 hours (5s*36767/3600 = 45 hours)

Property Value
Configuration ID config_3_2
Data Type INTEGER
Range 1 to 32767
Default Value 720

4: kWH Meter Report Period

6x10min = 1 hour

Property Value
Configuration ID config_4_2
Data Type INTEGER
Range 1 to 32767
Default Value 6

5: Threshold of Watt for load caution

Property Value
Configuration ID config_5_2
Data Type INTEGER
Range 10 to 3000
Default Value 3000

6: Threshold of kWH for load caution

Property Value
Configuration ID config_6_2
Data Type INTEGER
Range 0 to 10000
Default Value 0

7: Edge or Pulse mode or Edge-Toggle mode

1 - Edge mode 2 - Pulse mode 3 - Edge toggle mode

Property Value
Configuration ID config_7_1
Data Type INTEGER
Range 1 to 3
Default Value 3

1: Lifeline

Property Value
Configuration ID group_1
Data Type TEXT
Range to