Vitrum I EU Boiler Vitrum touch timer switch Dual Relay

This describes the Z-Wave device Vitrum I EU Boiler, manufactured by VDA with the thing type UID of vda_euboiler_00_000.

The Vitrum I EU Boiler does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the Vitrum I EU Boiler -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch
Dimmer switch_dimmer DimmableLight Dimmer
Scene Number scene_number   Number
Scene Number scene_number   Number
Switch 1 switch_binary1 Switch Switch
Dimmer 1 switch_dimmer1 DimmableLight Dimmer

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Dimmer

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel supports the Dimmer item and is in the DimmableLight category.

Scene Number

Triggers when a scene button is pressed.

The scene_number channel supports the Number item.

Scene Number

Triggers when a scene button is pressed.

The scene_number channel supports the Number item.

Switch 1

Switch the power on and off.

The switch_binary1 channel supports the Switch item and is in the Switch category.

Dimmer 1

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer1 channel supports the Dimmer item and is in the DimmableLight category.

Device Configuration

The device has no configuration parameters configured.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The device does not support associations.

Technical Information

Endpoints

Endpoint 0

| Command Class | Comment | |—————|———| | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| | COMMAND_CLASS_SWITCH_MULTILEVEL_V3| | | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_SCENE_ACTIVATION_V1| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1| | | COMMAND_CLASS_CENTRAL_SCENE_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_MULTI_CHANNEL_V2| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_NODE_NAMING_V1| | | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_VERSION_V2| | | COMMAND_CLASS_INDICATOR_V1| | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2| |

Endpoint 1

Command Class Comment
COMMAND_CLASS_BASIC_V0  
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_MULTILEVEL_V3  