DS100 Double Switch in a dual relay in-wall module.
This describes the Z-Wave device DS100, manufactured by Vemmio with the thing type UID of vemmio_ds100_00_000
.
Double Switch in a dual relay in-wall module.
Channels
The following table summarises the channels available for the DS100 Double Switch in a dual relay in-wall module..
Channel | Channel Id | Channel Type UID | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Scene Number | scene_number | scene_number | Number | |
Electric meter (power factor) | meter_powerfactor | meter_powerfactor | Energy | Number |
Electric meter (volts) | meter_voltage | meter_voltage | Energy | Number |
Electric meter (amps) | meter_current | meter_current | Energy | Number |
Electric meter (watts) | meter_watts | meter_watts | Energy | Number |
Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number |
Alarm | alarm_general | alarm_general | Door | Switch |
Switch 1 | switch_binary1 | switch_binary | Switch | Switch |
Electric meter (power factor) 1 | meter_powerfactor1 | meter_powerfactor | Energy | Number |
Electric meter (volts) 1 | meter_voltage1 | meter_voltage | Energy | Number |
Electric meter (amps) 1 | meter_current1 | meter_current | Energy | Number |
Electric meter (watts) 1 | meter_watts1 | meter_watts | Energy | Number |
Electric meter (kWh) 1 | meter_kwh1 | meter_kwh | Energy | Number |
Switch 2 | switch_binary2 | switch_binary | Switch | Switch |
Electric meter (power factor) 2 | meter_powerfactor2 | meter_powerfactor | Energy | Number |
Electric meter (volts) 2 | meter_voltage2 | meter_voltage | Energy | Number |
Electric meter (amps) 2 | meter_current2 | meter_current | Energy | Number |
Electric meter (watts) 2 | meter_watts2 | meter_watts | Energy | Number |
Electric meter (kWh) 2 | meter_kwh2 | meter_kwh | Energy | Number |
Switch 3 | switch_binary3 | switch_binary | Switch | Switch |
Electric meter (power factor) 3 | meter_powerfactor3 | meter_powerfactor | Energy | Number |
Electric meter (volts) 3 | meter_voltage3 | meter_voltage | Energy | Number |
Electric meter (amps) 3 | meter_current3 | meter_current | Energy | Number |
Electric meter (watts) 3 | meter_watts3 | meter_watts | Energy | Number |
Electric meter (kWh) 3 | meter_kwh3 | meter_kwh | Energy | Number |
Device Configuration
The following table provides a summary of the configuration parameters available in the DS100 Double Switch in a dual relay in-wall module.. Detailed information on each parameter can be found below.
Parameter | Description |
---|---|
0: Watt Meter Report Period | 720*5s=3600s=1hour |
2: KWH Meter Report Period | 6*10 min = 1 hour |
3: Selected Relay | 1: Relay 1, 2: Relay 2, 3: Relay 1 & Relay 2 |
4: Edge or Pulse mode or Edge-Toggle mode | 1: Edge mode, 2: Pulse mode, 3: Edge-Toggle mode |
5: Threshold of current for load caution | 750*0.01A=7.5A |
6: Threshold of KWH for load caution | |
7: Restore switch state mode | 0: Switch off, 1: Last switch, 2: Switch on |
8: Auto off timer | 0: Disable auto off function, 1: 0x0-0x7FFF 1s-32767s |
9: RF off command mode | 0: Switch off, 1: Ignore, 2: Switch toggle, 3: Switch on |
10: Existence of endpoint 3 | 1: endpoint 3 exists, 2: No endpoint 3 |
0: Watt Meter Report Period
720*5s=3600s=1hour
Property | Value |
---|---|
Configuration ID | config_0_2 |
Data Type | INTEGER |
Range | 1 to 32767 |
Default Value | 720 |
2: KWH Meter Report Period
6*10 min = 1 hour
Property | Value |
---|---|
Configuration ID | config_2_2 |
Data Type | INTEGER |
Range | 1 to 32767 |
Default Value | 6 |
3: Selected Relay
1: Relay 1, 2: Relay 2, 3: Relay 1 & Relay 2
Property | Value |
---|---|
Configuration ID | config_3_1 |
Data Type | INTEGER |
Range | 1 to 3 |
Default Value | 1 |
4: Edge or Pulse mode or Edge-Toggle mode
1: Edge mode, 2: Pulse mode, 3: Edge-Toggle mode
Property | Value |
---|---|
Configuration ID | config_4_1 |
Data Type | INTEGER |
Range | 1 to 3 |
Default Value | 1 |
5: Threshold of current for load caution
750*0.01A=7.5A
Property | Value |
---|---|
Configuration ID | config_5_2 |
Data Type | INTEGER |
Range | 10 to 750 |
Default Value | 750 |
6: Threshold of KWH for load caution
Property | Value |
---|---|
Configuration ID | config_6_2 |
Data Type | INTEGER |
Range | 1 to 10000 |
Default Value | 10000 |
7: Restore switch state mode
0: Switch off, 1: Last switch, 2: Switch on
Property | Value |
---|---|
Configuration ID | config_7_1 |
Data Type | INTEGER |
Range | 0 to 2 |
Default Value | 1 |
8: Auto off timer
0: Disable auto off function, 1: 0x0-0x7FFF 1s-32767s
Property | Value |
---|---|
Configuration ID | config_8_2 |
Data Type | INTEGER |
Range | 0 to 32767 |
Default Value | 0 |
9: RF off command mode
0: Switch off, 1: Ignore, 2: Switch toggle, 3: Switch on
Property | Value |
---|---|
Configuration ID | config_9_1 |
Data Type | INTEGER |
Range | 0 to 3 |
Default Value | 0 |
10: Existence of endpoint 3
1: endpoint 3 exists, 2: No endpoint 3
Property | Value |
---|---|
Configuration ID | config_10_1 |
Data Type | INTEGER |
Range | 1 to 2 |
Default Value | 1 |
Did you spot an error in the above definition or want to improve the content? You can edit the database here.