DS100 Double Switch in a dual relay in-wall module.

This describes the Z-Wave device DS100, manufactured by Vemmio with the thing type UID of vemmio_ds100_00_000.

Double Switch in a dual relay in-wall module.

Channels

The following table summarises the channels available for the DS100 Double Switch in a dual relay in-wall module..

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Scene Number scene_number scene_number   Number
Electric meter (power factor) meter_powerfactor meter_powerfactor Energy Number
Electric meter (volts) meter_voltage meter_voltage Energy Number
Electric meter (amps) meter_current meter_current Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Alarm alarm_general alarm_general Door Switch
Switch 1 switch_binary1 switch_binary Switch Switch
Electric meter (power factor) 1 meter_powerfactor1 meter_powerfactor Energy Number
Electric meter (volts) 1 meter_voltage1 meter_voltage Energy Number
Electric meter (amps) 1 meter_current1 meter_current Energy Number
Electric meter (watts) 1 meter_watts1 meter_watts Energy Number
Electric meter (kWh) 1 meter_kwh1 meter_kwh Energy Number
Switch 2 switch_binary2 switch_binary Switch Switch
Electric meter (power factor) 2 meter_powerfactor2 meter_powerfactor Energy Number
Electric meter (volts) 2 meter_voltage2 meter_voltage Energy Number
Electric meter (amps) 2 meter_current2 meter_current Energy Number
Electric meter (watts) 2 meter_watts2 meter_watts Energy Number
Electric meter (kWh) 2 meter_kwh2 meter_kwh Energy Number
Switch 3 switch_binary3 switch_binary Switch Switch
Electric meter (power factor) 3 meter_powerfactor3 meter_powerfactor Energy Number
Electric meter (volts) 3 meter_voltage3 meter_voltage Energy Number
Electric meter (amps) 3 meter_current3 meter_current Energy Number
Electric meter (watts) 3 meter_watts3 meter_watts Energy Number
Electric meter (kWh) 3 meter_kwh3 meter_kwh Energy Number

Device Configuration

The following table provides a summary of the configuration parameters available in the DS100 Double Switch in a dual relay in-wall module.. Detailed information on each parameter can be found below.

Parameter Description
0: Watt Meter Report Period 720*5s=3600s=1hour
2: KWH Meter Report Period 6*10 min = 1 hour
3: Selected Relay 1: Relay 1, 2: Relay 2, 3: Relay 1 & Relay 2
4: Edge or Pulse mode or Edge-Toggle mode 1: Edge mode, 2: Pulse mode, 3: Edge-Toggle mode
5: Threshold of current for load caution 750*0.01A=7.5A
6: Threshold of KWH for load caution  
7: Restore switch state mode 0: Switch off, 1: Last switch, 2: Switch on
8: Auto off timer 0: Disable auto off function, 1: 0x0-0x7FFF 1s-32767s
9: RF off command mode 0: Switch off, 1: Ignore, 2: Switch toggle, 3: Switch on
10: Existence of endpoint 3 1: endpoint 3 exists, 2: No endpoint 3

0: Watt Meter Report Period

720*5s=3600s=1hour

Property Value
Configuration ID config_0_2
Data Type INTEGER
Range 1 to 32767
Default Value 720

2: KWH Meter Report Period

6*10 min = 1 hour

Property Value
Configuration ID config_2_2
Data Type INTEGER
Range 1 to 32767
Default Value 6

3: Selected Relay

1: Relay 1, 2: Relay 2, 3: Relay 1 & Relay 2

Property Value
Configuration ID config_3_1
Data Type INTEGER
Range 1 to 3
Default Value 1

4: Edge or Pulse mode or Edge-Toggle mode

1: Edge mode, 2: Pulse mode, 3: Edge-Toggle mode

Property Value
Configuration ID config_4_1
Data Type INTEGER
Range 1 to 3
Default Value 1

5: Threshold of current for load caution

750*0.01A=7.5A

Property Value
Configuration ID config_5_2
Data Type INTEGER
Range 10 to 750
Default Value 750

6: Threshold of KWH for load caution

Property Value
Configuration ID config_6_2
Data Type INTEGER
Range 1 to 10000
Default Value 10000

7: Restore switch state mode

0: Switch off, 1: Last switch, 2: Switch on

Property Value
Configuration ID config_7_1
Data Type INTEGER
Range 0 to 2
Default Value 1

8: Auto off timer

0: Disable auto off function, 1: 0x0-0x7FFF 1s-32767s

Property Value
Configuration ID config_8_2
Data Type INTEGER
Range 0 to 32767
Default Value 0

9: RF off command mode

0: Switch off, 1: Ignore, 2: Switch toggle, 3: Switch on

Property Value
Configuration ID config_9_1
Data Type INTEGER
Range 0 to 3
Default Value 0

10: Existence of endpoint 3

1: endpoint 3 exists, 2: No endpoint 3

Property Value
Configuration ID config_10_1
Data Type INTEGER
Range 1 to 2
Default Value 1