ZM1602 AC/DC Siren

This describes the Z-Wave device ZM1602, manufactured by Vision Security with the thing type UID of vision_zm1602_15_000. This version of the device is limited to firmware versions above 15.0

The ZM1602 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the ZM1602 -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch
Alarm (burglar) alarm_burglar Door Switch

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Alarm (burglar)

Indicates if the burglar alarm is triggered.

The alarm_burglar channel supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF Ok
ON Alarm

Device Configuration

The following table provides a summary of the 2 configuration parameters available in the ZM1602. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Siren Strobe Mode Defines the reaction of the siren
2 Alarm auto stop Defines the auto time out of the alarm indication

Parameter 1: Siren Strobe Mode

Defines the reaction of the siren

The following option values may be configured -:

Value Description
0 Strobe and Siren
1 Siren
2 Strobe

The manufacturer defined default value is 0 (Strobe and Siren).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Alarm auto stop

Defines the auto time out of the alarm indication

The following option values may be configured -:

Value Description
0 30 seconds
1 60 seconds
2 120 seconds
3 Continuous

The manufacturer defined default value is 0 (30 seconds).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The device does not support associations.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1  
COMMAND_CLASS_BASIC_V1  
COMMAND_CLASS_SWITCH_BINARY_V1  
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1  
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1  
COMMAND_CLASS_ZWAVEPLUS_INFO_V1  
COMMAND_CLASS_CONFIGURATION_V1  
COMMAND_CLASS_ALARM_V4  
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1  
COMMAND_CLASS_POWERLEVEL_V1  
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1  
COMMAND_CLASS_ASSOCIATION_V2  
COMMAND_CLASS_VERSION_V2  
COMMAND_CLASS_SECURITY_V0  

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.