ZS6101 Smoke Detector

This describes the Z-Wave device ZS6101, manufactured by Vision Security with the thing type UID of vision_zs6101_00_000.

The device is in the category of Smoke Detector, defining Smoke detectors.

ZS6101 product image

The ZS6101 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

The ZS6101 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the ZS6101 -:

Channel Channel Id Category Item Type
Binary Sensor sensor_binary Door Switch
Alarm (smoke) alarm_smoke Door Switch
Battery Level battery-level Battery Number

Binary Sensor

Indicates if a sensor has triggered.

The sensor_binary channel supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
ON Triggered
OFF Untriggered

Alarm (smoke)

Indicates if a smoke is triggered.

The alarm_smoke channel supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF Ok
ON Alarm

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The battery-level channel supports the Number item and is in the Battery category.

Device Configuration

The device has no configuration parameters configured.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The ZS6101 supports 1 association group.

Group 1: Alarm Messages

This group supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1  
COMMAND_CLASS_BASIC_V1  
COMMAND_CLASS_SENSOR_BINARY_V1  
COMMAND_CLASS_ALARM_V1  
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1  
COMMAND_CLASS_BATTERY_V1  
COMMAND_CLASS_WAKE_UP_V2  
COMMAND_CLASS_ASSOCIATION_V1  
COMMAND_CLASS_VERSION_V1  

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.