The openHAB Documentation Has Moved

The documentation has moved to openhab.org/docs and openhab.org/addons.

Please use the link below to be redirected to the new version of this article, and update your bookmarks.

ZSE40 Zooz 4-in-one motion/temperature/humidity/luminance sensor

This describes the Z-Wave device ZSE40, manufactured by Vision Security with the thing type UID of vision_zse40_00_000.

The device is in the category of Motion Detector, defining Motion sensors/detectors.

ZSE40 product image

The ZSE40 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

The ZSE40 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour. The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the ZSE40 -:

Channel Channel Id Category Item Type
Sensor (motion) sensor_binary Door Switch
Sensor (luminance) sensor_luminance Temperature Number
Sensor (relative humidity) sensor_relhumidity Humidity Number
Sensor (temperature) sensor_temperature Temperature Number
Alarm (burglar) alarm_burglar Door Switch
Battery Level battery-level Battery Number

Sensor (motion)

This does not appear to be used, but the original authors of this device added it and I cannot figure out how to delete an item.

Indicates if a sensor has triggered.

The sensor_binary channel supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
ON Triggered
OFF Untriggered

Sensor (luminance)

Indicates the current light reading.

The sensor_luminance channel supports the Number item and is in the Temperature category. This is a read only channel so will only be updated following state changes from the device.

Sensor (relative humidity)

Indicates the current relative humidity.

The sensor_relhumidity channel supports the Number item and is in the Humidity category. This is a read only channel so will only be updated following state changes from the device.

Sensor (temperature)

Indicates the current temperature.

The sensor_temperature channel supports the Number item and is in the Temperature category. This is a read only channel so will only be updated following state changes from the device.

Alarm (burglar)

Motion PIR Sensor - Event 8 is motion; Event 3 is motion + tamper; Event 0 is clear.

Indicates if the burglar alarm is triggered.

The alarm_burglar channel supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF Ok
ON Alarm

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The battery-level channel supports the Number item and is in the Battery category.

Device Configuration

The following table provides a summary of the 7 configuration parameters available in the ZSE40. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Temperature Scale Set the temperature scale
2 Temperature offset  
3 Humidity Configure Relative Humidity
4 Light Sensor Configure Light Sensor
5 Trigger Interval Set the trigger interval for motion sensor re-activation.
6 Motion Sensor Sensitivity Adjust sensitivity of the motion sensor.
7 LED indicator mode Select the LED indicator mode
  Wakeup Interval Sets the interval at which the device will accept commands from the controller
  Wakeup Node Sets the node ID of the device to receive the wakeup notifications

Parameter 1: Temperature Scale

Set the temperature scale

The following option values may be configured -:

Value Description
0 Celsius
1 Fahrenheit

The manufacturer defined default value is 0 (Celsius).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Temperature offset

Values in the range 0 to 50 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Humidity

Configure Relative Humidity

Values in the range 1 to 50 may be set.

The manufacturer defined default value is 10.

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Light Sensor

Configure Light Sensor

Values in the range 1 to 50 may be set.

The manufacturer defined default value is 10.

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Trigger Interval

Set the trigger interval for motion sensor re-activation.

Values in the range 1 to 255 may be set.

The manufacturer defined default value is 180.

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 6: Motion Sensor Sensitivity

Adjust sensitivity of the motion sensor.

The following option values may be configured -:

Value Description
1 highest
2 higher
3 high
4 normal
5 low
6 lower
7 lowest

The manufacturer defined default value is 4 (normal).

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Parameter 7: LED indicator mode

Select the LED indicator mode

The following option values may be configured -:

Value Description
1 Off
2 Pulsing Temperature, Flashing Motion
3 Flashing Temperature and Motion

The manufacturer defined default value is 3 (Flashing Temperature and Motion).

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Wakeup Interval

The wakeup interval sets the period at which the device will listen for messages from the controller. This is required for battery devices that sleep most of the time in order to conserve battery life. The device will wake up at this interval and send a message to the controller to tell it that it can accept messages - after a few seconds, it will go back to sleep if there is no further communications.

This setting is defined in seconds. It is advisable not to set this interval too short or it could impact battery life. A period of 1 hour (3600 seconds) is suitable in most instances.

Note that this setting does not affect the devices ability to send sensor data, or notification events.

This parameter has the configuration ID wakeup_interval and is of type INTEGER.

Wakeup Node

When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address. In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.

This parameter has the configuration ID wakeup_node and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The ZSE40 supports 1 association group.

Group 1: Receive updates

Receive sensor updates This group supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1  
COMMAND_CLASS_BASIC_V1 Linked to BASIC
COMMAND_CLASS_SENSOR_MULTILEVEL_V7  
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1  
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1  
COMMAND_CLASS_ZWAVEPLUS_INFO_V2  
COMMAND_CLASS_CONFIGURATION_V1  
COMMAND_CLASS_ALARM_V1  
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1  
COMMAND_CLASS_POWERLEVEL_V1  
COMMAND_CLASS_BATTERY_V1  
COMMAND_CLASS_WAKE_UP_V2  
COMMAND_CLASS_ASSOCIATION_V2  
COMMAND_CLASS_VERSION_V2  
COMMAND_CLASS_SECURITY_V1  

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.