ZD2105 Recessed Door Window Sensor

This describes the Z-Wave device ZD2105, manufactured by Vision Security with the thing type UID of vision_zd2105_00_000.

Recessed Door Window Sensor

Overview

https://fccid.io/KFR-ZD2105US-5

or 

http://www.monoprice.com/product?p_id=15268

Inclusion Information

For “Inclusion” in (adding to) a network: Put the Z-WaveTM Interface Controller into “inclusion” mode, and following its instruction to add the ZD2105 to your controller. To get in the “inclusion” mode, please press the Program Switch of ZD2105 for sending the NIF. After sending NIF, Z-Wave will send the auto inclusion; otherwise, ZD2105 will go to sleep after 20 seconds

Exclusion Information

For “Exclusion” from (removing from) a network: Put the Z-WaveTM Interface Controller into “exclusion” mode, and following its instruction to delete the ZD2105 from your controller. Press the Program Switch of ZD2105 for 1 second at least to be excluded.

Note: All user and network settings will be cleared and the device reset to factory

Wakeup Information

Awake Mode:

It will be triggering after opening the cover, also the red LED will keep on lasting 10 seconds and ZD2105 will send “Wake Up Notification” after 10 seconds. If ZD2105 received “Wake Up No More Information” command then the red LED will go off or it will wait 10 seconds then go off. It will proceed all the commands after sending the “Wake Up Notification”

Channels

The following table summarises the channels available for the ZD2105 Recessed Door Window Sensor.

Channel Channel Id Channel Type UID Category Item Type
Door status sensor_door sensor_door Door Contact
Alarm (burglar) alarm_burglar alarm_burglar Door Switch
Alarm (access) alarm_access alarm_access Door Switch
  battery-level system.battery-level    

Device Configuration

The following table provides a summary of the configuration parameters available in the ZD2105 Recessed Door Window Sensor. Detailed information on each parameter can be found below.

Parameter Description
1: External switch Determines if external switch can be used.
1: Control Command  

1: External switch

Determines if external switch can be used.

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 0
Options Disabled (0)      
  Enabled (255)      

1: Control Command

Property Value
Configuration ID group_1
Data Type TEXT
Range to