ZD2201 Multisensor 4in1

This describes the Z-Wave device ZD2201, manufactured by Vision Security with the thing type UID of vision_zd2201_00_000.

Multisensor 4in1

Overview

Contact/temperature/humidity/luminance sensor.  Can also be called Zipato Quad Sensor (Z+).

Channels

The following table summarises the channels available for the ZD2201 Multisensor 4in1.

Channel Channel Id Channel Type UID Category Item Type
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number
Sensor (luminance) sensor_luminance sensor_luminance Temperature Number
Sensor (relative humidity) sensor_relhumidity sensor_relhumidity Humidity Number
Door sensor sensor_door sensor_door Door Contact
Tamper Alarm alarm_tamper alarm_tamper   Switch
  battery-level system.battery-level    

Sensor (temperature)

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Device Configuration

The following table provides a summary of the configuration parameters available in the ZD2201 Multisensor 4in1. Detailed information on each parameter can be found below.

Parameter Description
1: Temperature unit  
2: Temperature Reporting Threshold Set up from 0.1C to 5C
3: Humidity Reporting Threshold Set up from 1%-50%
4: Set up from 5%-50%
1: Lifeline  

1: Temperature unit

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 0
Options Celsius (default) (0)      
  Fahrenheit (1)      

2: Temperature Reporting Threshold

Set up from 0.1C to 5C

Overview

Threshold change in temperature to induce an automatic report. 1 to 50 ( Set up from 0.1C to 5C)

Property Value
Configuration ID config_2_1
Data Type INTEGER
Range 1 to 50
Default Value 1

3: Humidity Reporting Threshold

Set up from 1%-50%

Overview

Threshold change in humidity to induce an automatic report. 1 to 50 ( Set up from 1%-50%)

Property Value
Configuration ID config_3_1
Data Type INTEGER
Range 1 to 50
Default Value 10

4:

Set up from 5%-50%

Overview

Threshold change in luminance to induce an automatic report. 0 is disabled. 5 to 50 ( Set up from 5%-50%)

Property Value
Configuration ID config_4_1
Data Type INTEGER
Range 0 to 50
Default Value 10

1: Lifeline

Property Value
Configuration ID group_1
Data Type TEXT
Range to