NZW97 Inovelli Outdoor Smart Plug (2 Channel)

This describes the Z-Wave device NZW97, manufactured by Willis Electric Co., Ltd. with the thing type UID of willis_nzw97_00_000.

The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.

NZW97 product image

The NZW97 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.

Overview

2 Controllable Outlets

Outdoor IP65

20 cm Cord

High Temp Protection (OFF at 105°C)

Last Power State (Possible DEFAULT)

120 VAC, 60 Hz

908.42 MHz

Max Load Outlet #1 1800W (15A) Resistive

Max Load Outlet #2 1800W (15A) Resistive

Max Simultaneous Load 15A

Max Range LoS 100 m

Operating Temperature Range -20°C to 50°C

UL E464831

FCC ID OXGZW97

Inclusion Information

Auto-Inclusion 30 sec from power on

Backup-Inclusion Press button 5 times within 1 sec

(Tested to work with Network Wide Inclusion)

Channels

The following table summarises the channels available for the NZW97 -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch
Alarm (heat) alarm_heat   Switch
Switch 1 switch_binary1 Switch Switch
Switch 2 switch_binary2 Switch Switch

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Alarm (heat)

Indicates if a heat alarm is triggered.

The alarm_heat channel supports the Switch item. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF Ok
ON Alarm

Switch 1

Switch the power on and off.

The switch_binary1 channel supports the Switch item and is in the Switch category.

Switch 2

Switch the power on and off.

The switch_binary2 channel supports the Switch item and is in the Switch category.

Device Configuration

The following table provides a summary of the 1 configuration parameters available in the NZW97. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 LED Indicator LED Indicator ON/OFF/Disabled
  Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: LED Indicator

LED Indicator ON/OFF/Disabled LED Indicator ON/OFF/Disabled
00==Plug On / LED On
01==Plug On / LED Off
02==LED Disabled Values in the range 0 to 2 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_1_1_wo and is of type INTEGER. This is a write only parameter.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -: | Value | Description | |——–|————-| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups |

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The device does not support associations.

Technical Information

Endpoints

Endpoint 0

| Command Class | Comment | |—————|———| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_MULTI_CHANNEL_V2| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_ALARM_V8| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_VERSION_V2| | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3| |

Endpoint 1

| Command Class | Comment | |—————|———| | COMMAND_CLASS_BASIC_V0| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3| |

Endpoint 2

Command Class Comment
COMMAND_CLASS_BASIC_V0  
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1  
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1  
COMMAND_CLASS_ZWAVEPLUS_INFO_V1  
COMMAND_CLASS_ASSOCIATION_V2  
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3  