iShutter iShutter

This describes the Z-Wave device iShutter, manufactured by Wintop with the thing type UID of wintop_ishutter_00_000.

iShutter

Channels

The following table summarises the channels available for the iShutter iShutter.

| Channel | Channel Id | Channel Type UID | Category | Item Type | |———|————|——————|———-|———–|

Device Configuration

The following table provides a summary of the configuration parameters available in the iShutter iShutter. Detailed information on each parameter can be found below.

Parameter Description
1: Buttons Mode See overview
2: Automatically close after If not zero, automatically close blind after a user defined time
3: What to do on RF close command Defines how to interpret RF Off command.
4: Typical click timeout time used to differentiate click, hold, double and triple clicks
5: Invert buttons Invert buttons
6: Action on button press or hold Defines which command should be sent to Association group
7: LED mode Set LED indication mode
10: Full close time Time to go from opened to closed state.
11: Full open time Time to go from closed to open state
12: Node Id of the blocking device Id of the device which commands would not be Open/Close, but as block/unblock.
13: which command from blocking node to enable the protection Which command from blocking device is closed door and hence, unprotected.
14: Invert open and close relays Allow exchanging open and close relays
1: Click, press and hold of up/down buttons Click, press and hold of up/down buttons
2: Send Reports on blind state change Send Reports on blind state change

1: Buttons Mode

See overview

Overview

0 -> One push button

1 -> Two paddles with Power and Direction

2 -> Two toggle switch

3 -> Two buttons with neutral position 

One push button: One button is used (chose any), press while moving up and down, stops, while stopped moves to opposite direction to previous. Two buttons with neutral position: Up click moves up if stopped and stops if moving down, Down click moves down 

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 0
Options One push button (0)      
  Two paddles with Power and Direction (1)      
  Two toggle switch (2)      
  Two buttons with neutral position (3)      

2: Automatically close after

If not zero, automatically close blind after a user defined time

Property Value
Configuration ID config_2_2
Data Type INTEGER
Range 0 to 65535
Default Value 0

3: What to do on RF close command

Defines how to interpret RF Off command.

Overview

0 -> Close

1 -> Ignore

2 -> Open

3 -> Open if closed, otherwise Close

Can be used in conjunction with Auto Close function: Ignore - to open the door by motion detectors and close it back after some amount of time: in case of multiple motion detectors each would try to open that would that would break logics; Open - to open on both On and Off paddle press on the remote and close after some amount of time. Button close click will still work (if button operations are not disabled). Note that Dim Down command will still begin close motion. 

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 0
Options Close (0)      
  Ignore (1)      
  Open (2)      
  Open if closed, otherwise Close (3)      

4: Typical click timeout

time used to differentiate click, hold, double and triple clicks

Overview

1 - 100 -> in 10ms units

Property Value
Configuration ID config_4_1
Data Type INTEGER
Range 0 to 100
Default Value 50

5: Invert buttons

Invert buttons

Overview

0 -> No

1 -> Yes 

Property Value      
Configuration ID config_5_1      
Data Type INTEGER   Default Value 0
Options No (0)      
  Yes (1)      

6: Action on button press or hold

Defines which command should be sent to Association group

Overview

Defines which command should be sent to Association group on button press or hold. Scene mode will send 1 for Up event, 2 for Stop, 3 for Down.

1 -> Switch On, Off and dim using Basic Set and MultiLevel Start/Stop Changing

2 -> Send Scene 

Property Value      
Configuration ID config_6_1      
Data Type INTEGER   Default Value 1
Options Switch On, Off and dim using Basic Set (1)      
  Send Scene (2)      

7: LED mode

Set LED indication mode

Overview

0 -> Disabled

1 -> Show working state

2 -> Always on

3 -> Show opened state

4 -> Indicator Command Class

Property Value      
Configuration ID config_7_1      
Data Type INTEGER   Default Value 1
Options Disabled (0)      
  Show working state (1)      
  Always on (2)      
  Show opened state (3)      
  Indicator Command Class (4)      

10: Full close time

Time to go from opened to closed state.

Overview

Used to estimate the current level. Note that in Permanent motion mode the reported value would a be Closed or Opened, while all Basic and  multilevel Set values (1-99, 255) would Open except 0 value that would Close. 

Property Value
Configuration ID config_10_1
Data Type INTEGER
Range 0 to 255
Default Value 60

11: Full open time

Time to go from closed to open state

Overview

Time to go from closed to open state. This value may differ from Full close time for some blinds due to gravity. Used to estimate the current level. Note that in Permanent motion mode the reported value would a be Closed or Opened, while all Basic and Multilevel Set values (1-99, 255) would Open except 0 value that would Close

Property Value
Configuration ID config_11_1
Data Type INTEGER
Range 0 to 255
Default Value 60

12: Node Id of the blocking device

Id of the device which commands would not be Open/Close, but as block/unblock.

Overview

Id of the device which commands would be interpreted not as Open/Close, but as block/unblock. Usefull with door opening detector: if the door is open, block the blind not to break shades while they move.

Property Value
Configuration ID config_12_1
Data Type INTEGER
Range 0 to 255
Default Value 0

13: which command from blocking node to enable the protection

Which command from blocking device is closed door and hence, unprotected.

Overview

0 -> on On

1 -> on Off

Property Value      
Configuration ID config_13_1      
Data Type INTEGER   Default Value 0
Options on On (0)      
  on Off (1)      

14: Invert open and close relays

Allow exchanging open and close relays

Overview

Allow exchanging open and close relays if blind control is wired to the motor incorrectly 

0 -> No

1 -> Yes

Property Value      
Configuration ID config_14_1      
Data Type INTEGER   Default Value 0
Options No (0)      
  Yes (1)      

1: Click, press and hold of up/down buttons

Click, press and hold of up/down buttons

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Send Reports on blind state change

Send Reports on blind state change

Property Value
Configuration ID group_2
Data Type TEXT
Range to