ITEMP Contact and temperature sensor

This describes the Z-Wave device ITEMP, manufactured by Wintop with the thing type UID of wintop_itemp_00_000.

Contact and temperature sensor

Channels

The following table summarises the channels available for the ITEMP Contact and temperature sensor.

Channel Channel Id Channel Type UID Category Item Type
Binary Sensor sensor_binary sensor_binary Door Switch
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number
Alarm (CO2) alarm_co2 alarm_co2 Door Switch
  battery-level system.battery-level    

Sensor (temperature)

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Device Configuration

The following table provides a summary of the configuration parameters available in the ITEMP Contact and temperature sensor. Detailed information on each parameter can be found below.

Parameter Description
1: Reset to factory default Delete configuration but keeps inclusion
2: Command sent on external dry contact Configure what te external contact sends when trigger
5: Operating Mode Defines if the sensor is in normal wakeup mode or always on (drains battery fast)
6: Temperature Offset Can be used to calibrate the temperature sensors function. Calibrated as factory default.
1: Binary input Group  
2: Alarm Group  

1: Reset to factory default

Delete configuration but keeps inclusion

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 0
Options No (default) (0)      
  Execute reset (1)      

2: Command sent on external dry contact

Configure what te external contact sends when trigger

Property Value      
Configuration ID config_2_1      
Data Type INTEGER   Default Value 0
Options Alarm Resport Type 2 (default) (0)      
  Basic On or Basic Off (1)      

5: Operating Mode

Defines if the sensor is in normal wakeup mode or always on (drains battery fast)

Property Value      
Configuration ID config_5_1      
Data Type INTEGER   Default Value 1
Options Normal Wakeup (default) (1)      
  Always awake (3)      

6: Temperature Offset

Can be used to calibrate the temperature sensors function. Calibrated as factory default.

Property Value
Configuration ID config_6_2
Data Type INTEGER
Range 0 to 15300
Default Value 0

1: Binary input Group

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Alarm Group

Property Value
Configuration ID group_2
Data Type TEXT
Range to