Multisensor Multi-sensor

This describes the Z-Wave device Multisensor, manufactured by Wintop with the thing type UID of wintop_multisensor_00_000.

Multi-sensor

Channels

The following table summarises the channels available for the Multisensor Multi-sensor.

Channel Channel Id Channel Type UID Category Item Type
Binary Sensor sensor_binary sensor_binary Door Switch
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number
Alarm alarm_general alarm_general Door Switch
  battery-level system.battery-level    
Sensor (temperature) 1 sensor_temperature1 sensor_temperature Temperature Number
Sensor (luminance) 2 sensor_luminance2 sensor_luminance Temperature Number

Sensor (temperature)

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Sensor (temperature) 1

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Device Configuration

The following table provides a summary of the configuration parameters available in the Multisensor Multi-sensor. Detailed information on each parameter can be found below.

Parameter Description
1: Set to default Set all config values to default values (factory settings).
2: Mode Timeout The time used in mode 2 to turn the sensor off .
3: Switch off time Switch off time starts after timeout.
4: Sensitivity The sensitivity of the motion circuit
5: Mode The mode that is entered after detection
6: The temperature offset An offset for the temperature.
1: Group 1  

1: Set to default

Set all config values to default values (factory settings).

Property Value
Configuration ID config_1_1
Data Type INTEGER
Range 0 to 255
Default Value 0

2: Mode Timeout

The time used in mode 2 to turn the sensor off .

Overview

The time used in mode 2 to turn the sensor off . 

This Time will start running as soon as detection is seen.

Property Value
Configuration ID config_2_2
Data Type INTEGER
Range 0 to 3600
Default Value 900

3: Switch off time

Switch off time starts after timeout.

Overview

The switch off time will start running as soon as mode timeout is done. Motion sensor is turned on and when movement is de tected again the mode timeout (cfg param 1) will start running all over again. When switch off time is done a basic off message is s

Property Value
Configuration ID config_3_2
Data Type INTEGER
Range 0 to 7200
Default Value 2700

4: Sensitivity

The sensitivity of the motion circuit

Property Value
Configuration ID config_4_1
Data Type INTEGER
Range 0 to 127
Default Value 80

5: Mode

The mode that is entered after detection

Overview

Normal operation mode is default.

Property Value
Configuration ID config_5_1
Data Type INTEGER
Range 1 to 3
Default Value 2

6: The temperature offset

An offset for the temperature.

Overview

Param1,2: A signed integer to determine the offset off the temperature.

Property Value
Configuration ID config_6_2
Data Type INTEGER
Range -10 to 10
Default Value 0

1: Group 1

Property Value
Configuration ID group_1
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.