WTRFID Mini Keypad RFID/Z-Wave

This describes the Z-Wave device WTRFID, manufactured by Wintop with the thing type UID of wintop_wtrfid_00_000.

Mini Keypad RFID/Z-Wave

Channels

The following table summarises the channels available for the WTRFID Mini Keypad RFID/Z-Wave.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Alarm (burglar) alarm_burglar alarm_burglar Door Switch
Alarm (access) notification_access_control notification_access_control   Number
  battery-level system.battery-level    

Device Configuration

The following table provides a summary of the configuration parameters available in the WTRFID Mini Keypad RFID/Z-Wave. Detailed information on each parameter can be found below.

Parameter Description
1: Set to Default Set all configuration values to default values (factory settings).
2: Audible feedback config To configure the time the beep is automatically turned off in seconds.
3: Feedback timeout Feedback timeout
4: Feedback beeps per Second To configure the number of beeps per second. Every beep is fixed about 10ms.
5: Mode Configure the operating mode
1: Group1  

1: Set to Default

Set all configuration values to default values (factory settings).

Property Value
Configuration ID config_1_1
Data Type INTEGER
Range 1 to 255
Default Value 1

2: Audible feedback config

To configure the time the beep is automatically turned off in seconds.

Overview

The Mini Keypad RFiD/Z-Wave supports 3 types of notification sound configurations:

1 Notification sound disabled (configuration parameter 2 set to zero)
2 Notification sound enabled (default, configuration parameter 2 set to auto-stop time).
Property Value
Configuration ID config_2_1
Data Type INTEGER
Range 1 to 255
Default Value 15

3: Feedback timeout

Feedback timeout

Overview

To configure the timeout to wait for a WAKEUP_NO_MORE_INFORMATION before the error beep is automatically sound. The error beeps are fixed 8 beeps shortly after each other.       

0    ->   disabled

Property Value
Configuration ID config_3_1
Data Type INTEGER
Range 0 to 255
Default Value 0

4: Feedback beeps per Second

To configure the number of beeps per second. Every beep is fixed about 10ms.

Property Value
Configuration ID config_4_1
Data Type INTEGER
Range 1 to 255
Default Value 2

5: Mode

Configure the operating mode

Overview

To configure the operating mode. If any mode other then 3, that value will be reported after a get but will be handled in SW as mode 1.

5 The mode DESCRIPTION: To configure the operating mode. DEFAULT: 0x01 SIZE: 1 byte* PARAM1: MODE 1: Normal operating mode. MODE 3: Z-Wave chip is always on to request e.g. version or manufacturer id. If any mode other then 3, that value will be reported after a get but will be handled in SW as mode 1. PARAM2,3: not used.
Property Value
Configuration ID config_5_1
Data Type INTEGER
Range 1 to 255
Default Value 1

1: Group1

Property Value
Configuration ID group_1
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.