The openHAB Documentation Has Moved

The documentation has moved to openhab.org/docs and openhab.org/addons.

Please use the link below to be redirected to the new version of this article, and update your bookmarks.

SD-L1000-CH Yale Conexis L1

This describes the Z-Wave device SD-L1000-CH, manufactured by ASSA ABLOY with the thing type UID of yale_ycl1_00_000.

The device is in the category of Lock, defining Devices whose primary pupose is locking something.

SD-L1000-CH product image

The SD-L1000-CH supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

Overview

The future of Door Locks is here

Open the door to your world with the Conexis(R) L1 Smart Door Lock. The Smart Door Lock that puts you fully in control giving you the freedom to secure your home without the need for a key.

Send & Receive Virtual Keys

Control access from your smartphone

Keyless

Say goodbye to your keys

In-App Control

Control access from your smartphone

Inclusion Information

  1. Ensure the Z-Wave controller is close to the lock, around 1.5m.
  2. Remove the upper plastic cover from the lock, on the interior side.
  3. Set the controller into inclusion mode.
  4. Press the reset ‘R’ button 3 times in 1.5s (3 quick presses), the lock will beep twice.
  5. Upon connection, the lock will play 3 notes.

Exclusion Information

  1. Remove the upper plastic cover from the lock, on the interior side.
  2. Set the controller into exclusion mode.
  3. Press the reset ‘R’ button 3 times in 1.5s (3 quick presses), the lock will beep twice.
  4. Upon successful exclusion, the lock will play 3 notes.

Channels

The following table summarises the channels available for the SD-L1000-CH -:

Channel Channel Id Category Item Type
Door Lock lock_door Door Switch
Alarm alarm_general Door Switch
Battery Level battery-level Battery Number
Clock Time Offset time_offset Temperature Number

Door Lock

Lock and unlock the door.

The lock_door channel supports the Switch item and is in the Door category.

Alarm

Indicates if an alarm is triggered.

The alarm_general channel supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF Ok
ON Alarm

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The battery-level channel supports the Number item and is in the Battery category.

Clock Time Offset

Provides the current time difference for the devices time.

The time_offset channel supports the Number item and is in the Temperature category.

Device Configuration

The following table provides a summary of the 5 configuration parameters available in the SD-L1000-CH. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Volume Beep volume
2 Auto Re-lock The lock will re-lock automatically if untouched for the timeout
3 Re-lock time The amount of time which the lock will wait before re-locking
4 Wrong tag limit Number of wrong tags that can be tried before stand-down
7 Wrong tag timeout Time after the wrong tag limit being exceeded before re-trying
  Lock Timeout Sets the time after which the door will auto lock

Parameter 1: Volume

Beep volume 1 = Silent mode

2 = Low volume

3 = High volume (default) The following option values may be configured -:

Value Description
1 Silent
2 Low
3 High

The manufacturer defined default value is 3 (High).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Auto Re-lock

The lock will re-lock automatically if untouched for the timeout 0 = No auto re-lock (default)

255 = auto re-lock The following option values may be configured -:

Value Description
0 Off
255 On

The manufacturer defined default value is 0 (Off).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Re-lock time

The amount of time which the lock will wait before re-locking Re-lock time in seconds Values in the range 7 to 60 may be set.

The manufacturer defined default value is 30.

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Wrong tag limit

Number of wrong tags that can be tried before stand-down Number of wrong tags that can be tried before stand-down Values in the range 1 to 20 may be set.

The manufacturer defined default value is 20.

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 7: Wrong tag timeout

Time after the wrong tag limit being exceeded before re-trying Amount of time after the wrong tag limit being exceeded that the lock will stand-down for Values in the range 1 to 250 may be set.

The manufacturer defined default value is 250.

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Lock Timeout

Sets the time after which the door will auto lock.

This parameter has the configuration ID doorlock_timeout and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The SD-L1000-CH supports 1 association group.

Group 1: Lifeline

Z-Wave Plus Lifeline This group supports 1 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1  
COMMAND_CLASS_BASIC_V0  
COMMAND_CLASS_DOOR_LOCK_LOGGING_V1  
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1  
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1  
COMMAND_CLASS_ZWAVEPLUS_INFO_V1  
COMMAND_CLASS_DOOR_LOCK_V1  
COMMAND_CLASS_CONFIGURATION_V1  
COMMAND_CLASS_ALARM_V1  
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1  
COMMAND_CLASS_POWERLEVEL_V1  
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1  
COMMAND_CLASS_BATTERY_V1  
COMMAND_CLASS_ASSOCIATION_V2  
COMMAND_CLASS_VERSION_V2  
COMMAND_CLASS_TIME_V1  
COMMAND_CLASS_TIME_PARAMETERS_V1  
COMMAND_CLASS_SECURITY_V1  

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.