YKFCON Smart Living Keyfree Smart Lock

This describes the Z-Wave device YKFCON, manufactured by ASSA ABLOY with the thing type UID of yale_ykfcon_00_000.

Smart Living Keyfree Smart Lock

Channels

The following table summarises the channels available for the YKFCON Smart Living Keyfree Smart Lock.

Channel Channel Id Channel Type UID Category Item Type
Door Lock lock_door lock_door Door Switch
Alarm alarm_general alarm_general Door Switch
  battery-level system.battery-level    

Device Configuration

The following table provides a summary of the configuration parameters available in the YKFCON Smart Living Keyfree Smart Lock. Detailed information on each parameter can be found below.

Parameter Description
1: Audio Volume Sets the volume level of the beeps and voice prompts
2: Auto Re-lock When enabled, the unit will automatically re-lock
3: Re-lock Time Time after unlocking that the device will lock
4: Wrong Code Entry Limit The number of invalid tries before the lock shutdowns and sends an alarm
5: Language Language used by the voice prompts
7: Shutdown Time Number of times the device is locked out after the invalid retries are exceeded
8: Operating Mode Sets if the unit operates normal, or disables keypad and Z-Wave lock/unlock
1: Alarm Reports Alarm reports are sent out to all devices in the association group

1: Audio Volume

Sets the volume level of the beeps and voice prompts

Overview

1 = Silent

2 = Low

3 = High

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 3
Options Silent (1)      
  Low (2)      
  High (3)      

2: Auto Re-lock

When enabled, the unit will automatically re-lock

Overview

0 = Off

255 = On

Property Value      
Configuration ID config_2_1      
Data Type INTEGER   Default Value 0
Options Off (0)      
  On (255)      

3: Re-lock Time

Time after unlocking that the device will lock

Property Value
Configuration ID config_3_1
Data Type INTEGER
Range 5 to 255
Default Value 30

4: Wrong Code Entry Limit

The number of invalid tries before the lock shutdowns and sends an alarm

Property Value
Configuration ID config_4_1
Data Type INTEGER
Range 1 to 7
Default Value 5

5: Language

Language used by the voice prompts

Overview

1 = English

2 = Spanish

3 = French

Property Value      
Configuration ID config_5_1      
Data Type INTEGER   Default Value 1
Options English (1)      
  Spanish (2)      
  French (3)      

7: Shutdown Time

Number of times the device is locked out after the invalid retries are exceeded

Property Value
Configuration ID config_7_1
Data Type INTEGER
Range 1 to 255
Default Value 30

8: Operating Mode

Sets if the unit operates normal, or disables keypad and Z-Wave lock/unlock

Overview

0 = Normal

1 = Vacation Mode (User Codes Disabled)

2 = Privacy Mode (User Codes and ZWave Codes Disabled

Property Value      
Configuration ID config_8_1      
Data Type INTEGER   Default Value 0
Options Normal (0)      
  Vacation Mode (1)      
  Privacy Mode (2)      

1: Alarm Reports

Alarm reports are sent out to all devices in the association group

Property Value
Configuration ID group_1
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.