YRD110 Yale button deadbolt without keyway

This describes the Z-Wave device YRD110, manufactured by ASSA ABLOY with the thing type UID of yale_yrd110_00_000.

Yale button deadbolt without keyway

Channels

The following table summarises the channels available for the YRD110 Yale button deadbolt without keyway.

Channel Channel Id Channel Type UID Category Item Type
Door Lock lock_door lock_door Door Switch
Alarm (access) alarm_access alarm_access Door Switch
Alarm (power) alarm_power alarm_power Door Switch
Alarm (raw) alarm_raw alarm_raw   String
Clock Time Offset time_offset time_offset Temperature Number

Clock Time Offset

Automatic Update Offset

The number of seconds difference in the time before it is reset
Setting this will automatically update the devices clock when the time difference between the device, and the computer exceeds this number of seconds.

Property Value      
Configuration ID config_offset      
Data Type INTEGER      
Range 10 to 600   Default Value 60
Options Disable Auto Update (0)      

Device Configuration

The following table provides a summary of the configuration parameters available in the YRD110 Yale button deadbolt without keyway. Detailed information on each parameter can be found below.

Parameter Description
1: Volume Volume of beeps
2: Auto relock Auto relocking after unlocked
3: Auto relock time Time for auto relock
4: Wrong code limit Number of incorrect PINs before lockout
7: Shutdown time Incorrect attempts shutdown time
8: Operation Mode Operation Mode
1: Receive Alarms Group that will receive alarm notices from the lock

1: Volume

Volume of beeps

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 1
Options (0)      
  Loud (1)      
  Silent (3)      

2: Auto relock

Auto relocking after unlocked

Property Value      
Configuration ID config_2_1      
Data Type INTEGER   Default Value 0
Options No auto-relock (0)      
  Auto relock (255)      

3: Auto relock time

Time for auto relock

Overview

Amount of seconds between the door is unlocked and when it automatically attempts to re-lock itself, when auto-relocking is enabled.

Property Value
Configuration ID config_3_1
Data Type INTEGER
Range 5 to 255
Default Value 30

4: Wrong code limit

Number of incorrect PINs before lockout

Overview

Number of incorrect PINs that can be keyed in before lock goes into temporary keypad lockout mode.

Property Value
Configuration ID config_4_1
Data Type INTEGER
Range 1 to 7
Default Value 5

7: Shutdown time

Incorrect attempts shutdown time

Overview

Amount of time lock should ignore the keypad, if the number of incorrect PINs is exceeded.  (Can still be locked and unlocked by zwave while in shutdown.)

Property Value
Configuration ID config_7_1
Data Type INTEGER
Range 1 to 255
Default Value 60

8: Operation Mode

Operation Mode

Property Value      
Configuration ID config_8_1      
Data Type INTEGER   Default Value 0
Options Normal (0)      
  vacation (1)      
  privacy (2)      

1: Receive Alarms

Group that will receive alarm notices from the lock

Overview

The lock supports 1 association group with 5 devices. Alarm Reports are sent out unsolicited to devices included in the association group.

Property Value
Configuration ID group_1
Data Type TEXT
Range to