YRD210 Push Button Deadbolt

This describes the Z-Wave device YRD210, manufactured by ASSA ABLOY with the thing type UID of yale_yrd210_00_000.

Push Button Deadbolt

Channels

The following table summarises the channels available for the YRD210 Push Button Deadbolt.

Channel Channel Id Channel Type UID Category Item Type
  lock_door lock_door Door Switch
Alarm alarm_general alarm_general Door Switch
Alarm Raw alarm_raw alarm_raw   String
  battery-level system.battery-level    

Device Configuration

The following table provides a summary of the configuration parameters available in the YRD210 Push Button Deadbolt. Detailed information on each parameter can be found below.

Parameter Description
1: Audio Mode  
2: Auto relock  
3: Relock time Seconds; after successful code entry and unit unlocks, it will automatically re-lock after…
4: Wrong Code Entry Limit The number of invalid code entries lock will accept before sending TAMPER Alarm. When numb…
5: Language  
7: Shutdown Time Number of seconds unit will be inoperable after number of wrong code entries is exceeded.
8: Operating Mode  
1: Alarm Reports  

1: Audio Mode

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 3
Options Silent (1)      
  Low (2)      
  High (3)      

2: Auto relock

Property Value      
Configuration ID config_2_1      
Data Type INTEGER   Default Value 255
Options Off (0)      
  On (255)      

3: Relock time

Seconds; after successful code entry and unit unlocks, it will automatically re-lock after specified time

Property Value
Configuration ID config_3_1
Data Type INTEGER
Range 5 to 255
Default Value 30

4: Wrong Code Entry Limit

The number of invalid code entries lock will accept before sending TAMPER Alarm. When number of wrong code entries is exceeded, lock will disable keypad for the time specified by Shutdown Time parameter.

Property Value
Configuration ID config_4_1
Data Type INTEGER
Range 1 to 7
Default Value 5

5: Language

Property Value      
Configuration ID config_5_1      
Data Type INTEGER   Default Value 1
Options English (1)      
  Spanish (2)      
  French (3)      

7: Shutdown Time

Number of seconds unit will be inoperable after number of wrong code entries is exceeded.

Property Value
Configuration ID config_7_1
Data Type INTEGER
Range 1 to 255
Default Value 30

8: Operating Mode

Overview

Normal Mode

Vacation Mode - all user codes disabled

Privacy Mode - all user codes disabled and RF Lock/Unlock disabled

Property Value      
Configuration ID config_8_1      
Data Type INTEGER   Default Value 0
Options Normal (0)      
  Vacation (1)      
  Privacy (2)      

1: Alarm Reports

Property Value
Configuration ID group_1
Data Type TEXT
Range to