YRD246 Touchscreen deadbolt without keyway

This describes the Z-Wave device YRD246, manufactured by ASSA ABLOY with the thing type UID of yale_yrd246_00_000.

Touchscreen deadbolt without keyway

Channels

The following table summarises the channels available for the YRD246 Touchscreen deadbolt without keyway.

Channel Channel Id Channel Type UID Category Item Type
Door Lock lock_door lock_door Door Switch
Alarm (access) alarm_access alarm_access Door Switch
Alarm (power) alarm_power alarm_power Door Switch
Alarm (raw) alarm_raw alarm_raw   String
  battery-level system.battery-level    
Clock Time Offset time_offset time_offset Temperature Number

Clock Time Offset

Automatic Update Offset

The number of seconds difference in the time before it is reset
Setting this will automatically update the devices clock when the time difference between the device, and the computer exceeds this number of seconds.

Property Value      
Configuration ID config_offset      
Data Type INTEGER      
Range 10 to 600   Default Value 60
Options Disable Auto Update (0)      

Device Configuration

The following table provides a summary of the configuration parameters available in the YRD246 Touchscreen deadbolt without keyway. Detailed information on each parameter can be found below.

Parameter Description
1: Volume Volume of voice and beeps
2: Auto relock Automatic relocking
3: Auto relock time Time for auto relock
4: Incorrect PIN limit Number of incorrect PINs before lockout
6: Radio event reporting  
7: Keypad lockout time Incorrect PINs lockout time
8: Operation Mode Operation Mode
1: Lifeline  

1: Volume

Volume of voice and beeps

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 1
Options Loud (1)      
  Quiet (2)      
  Silent (3)      

2: Auto relock

Automatic relocking

Property Value      
Configuration ID config_2_1      
Data Type INTEGER   Default Value 0
Options No auto-relock (0)      
  Auto relock (255)      

3: Auto relock time

Time for auto relock

Overview

Number of seconds after the door is unlocked that it will attempt to automatically re-lock itself, if enabled.

Property Value
Configuration ID config_3_1
Data Type INTEGER
Range 5 to 255
Default Value 30

4: Incorrect PIN limit

Number of incorrect PINs before lockout

Overview

Number of incorrect PINs that can be attempted before lock goes into temporary keypad lockout.

Property Value
Configuration ID config_4_1
Data Type INTEGER
Range 1 to 7
Default Value 5

6: Radio event reporting

Property Value      
Configuration ID config_6_1      
Data Type INTEGER   Default Value 255
Options Don't report events? (0)      
  Do report events? (255)      

7: Keypad lockout time

Incorrect PINs lockout time

Overview

Amount of time to lock-out the keypad once the number of incorrect PINs has been reached on the keypad.  (Zwave is still active during lockout.)

Property Value
Configuration ID config_7_1
Data Type INTEGER
Range 1 to 255
Default Value 60

8: Operation Mode

Operation Mode

Property Value      
Configuration ID config_8_1      
Data Type INTEGER   Default Value 0
Options Normal (0)      
  Vacation (1)      
  Privacy (2)      
  Disable Zwave (3)      

1: Lifeline

Property Value
Configuration ID group_1
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.