YRD446 Yale Real Living Key Free Touchscreen Assure Lock with Z-Wave and Bluetooth

This describes the Z-Wave device YRD446, manufactured by ASSA ABLOY with the thing type UID of yale_yrd446_00_000.

Yale Real Living Key Free Touchscreen Assure Lock with Z-Wave and Bluetooth

Channels

The following table summarises the channels available for the YRD446 Yale Real Living Key Free Touchscreen Assure Lock with Z-Wave and Bluetooth.

Channel Channel Id Channel Type UID Category Item Type
Door Lock lock_door lock_door Door Switch
Auto Relock config_decimal_param2 yale_yrd446_00_000_config_decimal_param2   Number
Auto relock time config_decimal_param3 config_decimal   Decimal
Operating mode config_decimal_param8 yale_yrd446_00_000_config_decimal_param8    
Alarm (access) alarm_access alarm_access Door Switch
Alarm (power) alarm_power alarm_power Door Switch
Alarm (raw) alarm_raw alarm_raw   String
Alarm (general) alarm_general alarm_general Door Switch
  battery-level system.battery-level    
Clock Time Offset time_offset time_offset Temperature Number

Clock Time Offset

Automatic Update Offset

The number of seconds difference in the time before it is reset
Setting this will automatically update the devices clock when the time difference between the device, and the computer exceeds this number of seconds.

Property Value      
Configuration ID config_offset      
Data Type INTEGER      
Range 10 to 600   Default Value 60
Options Disable Auto Update (0)      

Device Configuration

The following table provides a summary of the configuration parameters available in the YRD446 Yale Real Living Key Free Touchscreen Assure Lock with Z-Wave and Bluetooth. Detailed information on each parameter can be found below.

Parameter Description
1: Volume Volume of voice and beeps
2: Auto relock  
3: Auto relock time Time for auto relock
4: Incorrect PIN limit Number of incorrect PINs before lockout
5: Language  
7: Shutdown Shutdown time after wrong code entries
8: Operating mode  
11: One Touch Locking  
12: Privacy Button  
13: Lock Status LED  
15: Reset To Factory Defaults  
1: Lifeline  

1: Volume

Volume of voice and beeps

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 1
Options Loud (1)      
  Quiet (2)      
  Silent (3)      

2: Auto relock

Property Value      
Configuration ID config_2_1      
Data Type INTEGER   Default Value 0
Options No auto-relock (0)      
  Auto relock (255)      

3: Auto relock time

Time for auto relock

Overview

Number of seconds after the door is unlocked that it will attempt to automatically re-lock itself, if enabled.

Property Value
Configuration ID config_3_1
Data Type INTEGER
Range 5 to 255
Default Value 30

4: Incorrect PIN limit

Number of incorrect PINs before lockout

Overview

Number of incorrect PINs that can be attempted before lock goes into temporary keypad lockout.

Property Value
Configuration ID config_4_1
Data Type INTEGER
Range 1 to 7
Default Value 5

5: Language

Property Value      
Configuration ID config_5_1      
Data Type INTEGER   Default Value 1
Options English (1)      
  Spanish (2)      
  French (3)      

7: Shutdown

Shutdown time after wrong code entries

Property Value
Configuration ID config_7_1
Data Type INTEGER
Range 10 to 127
Default Value 60

8: Operating mode

Property Value      
Configuration ID config_8_1      
Data Type INTEGER   Default Value 0
Options Normal (0)      
  Vacation (1)      
  Privacy (2)      

11: One Touch Locking

Property Value      
Configuration ID config_11_1      
Data Type INTEGER   Default Value 255
Options Off (0)      
  On (255)      

12: Privacy Button

Property Value      
Configuration ID config_12_1      
Data Type INTEGER   Default Value 0
Options Off (0)      
  On (255)      

13: Lock Status LED

Property Value      
Configuration ID config_13_1      
Data Type INTEGER   Default Value 0
Options Off (0)      
  On (255)      

15: Reset To Factory Defaults

Property Value      
Configuration ID config_15_1      
Data Type INTEGER   Default Value 0
Options Factory Reset (1)      

1: Lifeline

Property Value
Configuration ID group_1
Data Type TEXT
Range to