ZEN15 Power Switch

This describes the Z-Wave device ZEN15, manufactured by Zooz with the thing type UID of zooz_zen15_00_000.

ZEN15 product image

The ZEN15 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data from other devices.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the ZEN15 -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch
Scene Number scene_number   Number
Electric meter (volts) meter_voltage Energy Number
Electric meter (amps) meter_current Energy Number
Electric meter (kWh) meter_kwh Energy Number
Electric meter (watts) meter_watts Energy Number

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Scene Number

Triggers when a scene button is pressed.

The scene_number channel supports the Number item.

Electric meter (volts)

Indicates the instantaneous voltage.

The meter_voltage channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (amps)

Indicates the instantaneous current consumption.

The meter_current channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Device Configuration

The following table provides a summary of the 3 configuration parameters available in the ZEN15. Detailed information on each parameter can be found in the sections below.

Param Name Description
20 Overload Protection Overload protection.
21 On/Off Status Recovery After Power Failure Choose the recovery state for your Power Switch if power outage occurs.
24 On/Off Status Change Notifications Send On/Off Status Change Notifications
  Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 20: Overload Protection

Overload protection. Overload protection will turn the Power Switch relay off once power exceeds 16.5A for over 5 seconds when this setting is enabled.

We DO NOT recommend changing this parameter’s value as it may result in device damage and malfunction. The following option values may be configured -:

Value Description
0 Disabled
1 Enabled

The manufacturer defined default value is 1 (Enabled).

This parameter has the configuration ID config_20_1 and is of type INTEGER.

Parameter 21: On/Off Status Recovery After Power Failure

Choose the recovery state for your Power Switch if power outage occurs.

The following option values may be configured -:

Value Description
0 Previous state
1 ON
2 OFF

The manufacturer defined default value is 0 (Previous state).

This parameter has the configuration ID config_21_1 and is of type INTEGER.

Parameter 24: On/Off Status Change Notifications

Send On/Off Status Change Notifications Your Power Switch will automatically send a notification to the controller and other associated devices if its status changes from on to off or the other way round. Choose when you want it to send the report. The following option values may be configured -:

Value Description
0 Disabled
1 Sends notification if status is changed manually or remotely
2 Sends notification ONLY if status is changed manually

The manufacturer defined default value is 1 (Sends notification if status is changed manually or remotely).

This parameter has the configuration ID config_24_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -: | Value | Description | |——–|————-| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups |

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The ZEN15 supports 1 association group.

Group 1: Group 1

This group supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1  
COMMAND_CLASS_BASIC_V0  
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1  
COMMAND_CLASS_SCENE_ACTIVATION_V1  
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1  
COMMAND_CLASS_METER_V3  
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1  
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1  
COMMAND_CLASS_ZWAVEPLUS_INFO_V1  
COMMAND_CLASS_CONFIGURATION_V1  
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1  
COMMAND_CLASS_POWERLEVEL_V1  
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1  
COMMAND_CLASS_ASSOCIATION_V2  
COMMAND_CLASS_VERSION_V2  

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.