ZEN07 Mini Plug On / Off Module ZEN07

This describes the Z-Wave device ZEN07, manufactured by Zooz with the thing type UID of zooz_zen07_00_000.

Mini Plug On / Off Module ZEN07

Channels

The following table summarises the channels available for the ZEN07 Mini Plug On / Off Module ZEN07.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (amps) meter_current meter_current Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (volts) meter_voltage meter_voltage Energy Number
Alarm (power) alarm_power alarm_power Door Switch

Device Configuration

The following table provides a summary of the configuration parameters available in the ZEN07 Mini Plug On / Off Module ZEN07. Detailed information on each parameter can be found below.

Parameter Description
1: Metering Report send metering reports
2: Metering Report Frequency Frecuency metering reports to the controller.
3: Overload Protection Maximum amount of electricity Mini Plug to handle.
4: Overload Protection Notification LED notifications of heavy load.
5: LED Notifications Use this parameter to turn LED notifications on or off
6: Power Report Percentage Threshold Mini Plug to report energy usage percentage rate.
7: On/Off Status Recovery After Power Failure Choose the recovery state for your Mini Plug if power outage occurs
8: Auto Turn-Off Timer Enable : Use this parameter to enable or disable the auto turn-off timer function
9: Auto Turn-Off Timer Interval Set the time to automatically turn off
10: Manual Control Turn the Mini Plug with button

1: Metering Report

send metering reports

Overview

Choose if you want the Mini Plug to send metering reports to the controller. Values: 0 – Disabled; 1 – Enabled (default).

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 1
Options Disabled (0)      
  Enabled (default). (1)      

2: Metering Report Frequency

Frecuency metering reports to the controller.

Overview

Choose how often you want the Mini Plug to send metering reports to the controller. The number entered as the value corresponds to the number of seconds. So if 300 is entered by default, the Mini Plug will report power consumption every 300 seconds (5 minutes).

Property Value
Configuration ID config_2_2
Data Type INTEGER
Range 1 to 65535
Default Value 300

3: Overload Protection

Maximum amount of electricity Mini Plug to handle.

Overview

Use this parameter to adjust the maximum amount of electricity you want your Mini Plug to handle. The number entered as the value corresponds to the number of Amperes. Overload protection will turn the Mini Plug’s relay off once load exceeds 13A by default. It will also send a notification (NOTIFICATION_EVENT_POWER_MANAGEMENT_OVER_LOAD_DETECTED) to the controller and all associated devices. LED indicator on the device will blink red until the load is disconnected. Press the Z-Wave button ONCE to switch the alarm off. The value set in this parameter needs to be greater than the value in parameter 4. 

Property Value
Configuration ID config_3_1
Data Type INTEGER
Range 1 to 16
Default Value 13

4: Overload Protection Notification

LED notifications of heavy load.

Overview

Use this parameter to adjust electricity value for LED notifications of heavy load. The LED indicator on the Mini Plug will light up yellow once electricity from the load is greater than the value set in this parameter. The relay will NOT turn off. The value set in this parameter can NOT be greater than the value in parameter 3. Values: 1 – 13 (Amperes) or whatever the value set in parameter 3. 12 (Amperes) – default setting. 

Property Value
Configuration ID config_4_1
Data Type INTEGER
Range 1 to 13
Default Value 12

5: LED Notifications

Use this parameter to turn LED notifications on or off

Overview

Use this parameter to turn LED notifications on or off. Values: 0 – LED disabled; 1 – LED enabled (default).

Property Value      
Configuration ID config_5_1      
Data Type INTEGER   Default Value 1
Options LED disabled (0)      
  LED enabled (default) (1)      

6: Power Report Percentage Threshold

Mini Plug to report energy usage percentage rate.

Overview

Choose how you want your Mini Plug to report power consumption, electricity, voltage, and energy usage to your controller and associated devices by percentage rate. The number entered as the value corresponds to the change in percentage the appliance needs to go over for the event to be reported. So if 5% is entered by default, the Mini Plug will report any change in power consumption (W), voltage (V), electricity (A), or energy usage (kWH) over 5% (whether it’s at least 5% more or 5% less compared to previous report). Values: 1 – 100 (%); 5 (%) – default setting

Property Value
Configuration ID config_6_1
Data Type INTEGER
Range 1 to 100
Default Value 5

7: On/Off Status Recovery After Power Failure

Choose the recovery state for your Mini Plug if power outage occurs

Overview

Choose the recovery state for your Mini Plug if power outage occurs. Values: 0 – Mini Plug automatically turns OFF once power is restored (it does not remember the status prior to power outage); 1 – Mini Plug remembers the status prior to power outage and turns back to it (default); 

Property Value      
Configuration ID config_7_1      
Data Type INTEGER   Default Value 1
Options OFF once power is restored (0)      
  Remembers the status (1)      

8: Auto Turn-Off Timer Enable

: Use this parameter to enable or disable the auto turn-off timer function

Overview

Use this parameter to enable or disable the auto turn-off timer function. If this feature is enabled, the Mini Plug will automatically turn off after a fixed period of time (set in parameter 9). Values: 0 – timer disabled (default); 1 – timer enabled 

Property Value      
Configuration ID config_8_1      
Data Type INTEGER   Default Value 0
Options timer disabled (default) (0)      
  timer enabled (1)      

9: Auto Turn-Off Timer Interval

Set the time to automatically turn off

Overview

Use this parameter to set the time after which you want the Mini Plug to automatically turn off once it has been turned on. The number entered as value corresponds to the number of minutes. Values: 1 – 65535 (minutes); 150 (minutes) – default setting. 

Property Value
Configuration ID config_9_2
Data Type INTEGER
Range 1 to 65535
Default Value 150

10: Manual Control

Turn the Mini Plug with button

Overview

Choose if you want to use the Z-Wave button to turn the Mini Plug on or off manually or if you want to disable this function. If this parameter is set to 0 (disabled), you will only be able to turn the Mini Plug on or off remotely using your Z-Wave gateway controller. Values: 0 – manual control disabled; 1 – manual control enabled (default) 

Property Value      
Configuration ID config_10_1      
Data Type INTEGER   Default Value 1
Options manual control disabled (0)      
  manual control enabled (default) (1)      

Did you spot an error in the above definition or want to improve the content? You can edit the database here.