ZEN15 Power Switch

This describes the Z-Wave device ZEN15, manufactured by Zooz with the thing type UID of zooz_zen15_00_000.

Power Switch

Channels

The following table summarises the channels available for the ZEN15 Power Switch.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Scene Number scene_number scene_number   Number
Electric meter (volts) meter_voltage meter_voltage Energy Number
Electric meter (amps) meter_current meter_current Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number

Device Configuration

The following table provides a summary of the configuration parameters available in the ZEN15 Power Switch. Detailed information on each parameter can be found below.

Parameter Description
20: Overload Protection Overload protection.
21: On/Off Status Recovery After Power Failure Choose the recovery state for your Power Switch if power outage occurs.
24: On/Off Status Change Notifications Send On/Off Status Change Notifications
1: Group 1  

20: Overload Protection

Overload protection.

Overview

Overload protection will turn the Power Switch relay off once power exceeds 16.5A for over 5 seconds when this setting is enabled.

We DO NOT recommend changing this parameter’s value as it may result in device damage and malfunction.

Property Value      
Configuration ID config_20_1      
Data Type INTEGER   Default Value 1
Options Disabled (0)      
  Enabled (1)      

21: On/Off Status Recovery After Power Failure

Choose the recovery state for your Power Switch if power outage occurs.

Property Value      
Configuration ID config_21_1      
Data Type INTEGER   Default Value 0
Options Previous state (0)      
  ON (1)      
  OFF (2)      

24: On/Off Status Change Notifications

Send On/Off Status Change Notifications

Overview

Your Power Switch will automatically send a notification to the controller and other associated devices if its status changes from on to off or the other way round. Choose when you want it to send the report.

Property Value      
Configuration ID config_24_1      
Data Type INTEGER   Default Value 1
Options Disabled (0)      
  Sends notification if status is changed manually or remotely (1)      
  Sends notification ONLY if status is changed manually (2)      

1: Group 1

Property Value
Configuration ID group_1
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.