ZEN24 Z-Wave Plus Toggle Dimmer Light Switch Ver 2.0

This describes the Z-Wave device ZEN24, manufactured by Zooz with the thing type UID of zooz_zen24_00_000.

Z-Wave Plus Toggle Dimmer Light Switch Ver 2.0

Overview

  • Manual or remote on/off and dimming control from your mobile device or computer (when included to a Z-Wave gateway controller)
  • Universal 3-way capability – works with existing 3-way switches as long as neutral is present
  • Z-Wave Plus with improved 500 chip for faster and safer wireless communication
  • Works with LED, CFL, and incandescent bulbs
  • Remembers and restores on/off / brightness status after power failure
  • Based on universal multilevel switch command class - supported by most Z-Wave controllers
  • May be associated and grouped with other Z-Wave devices for advanced home automation
  • Air-gap switch for added safety
  • Classic toggle design
  • Built-in Z-Wave signal repeater for a stronger, more reliable network

Inclusion Information

  1. Bring your Z-Wave gateway hub or controller as close to the switch as possible

  2. Put your Z-Wave controller into inclusion mode

  3. Toggle the switch UP 3 times very quickly to finalize the inclusion process

  4. A new dimming device will appear on your controller’s device list

TROUBLESHOOTING TIPS:

If you are unable to include the Z-Wave switch to your controller, please try one of the following:

  • Bring the controller closer to your ZWave switch or use a hand-held secondary controller for inclusion
  • Toggle your Z-Wave switch UP even quicker at least 5 or 7 times once you put the controller into inclusion mode to ensure the command has gone through
  • Put your controller into EXCLUSION mode and toggle the switch DOWN 3 times quickly, then try adding it to your network again

Exclusion Information

  1. Bring your Z-Wave gateway hub or controller as close to the switch as possible

  2. Put your Z-Wave controller into exclusion mode 3. Toggle the switch DOWN

3 times very quickly to complete the exclusion process

  1. The device will disappear from your controller’s device list

Please repeat the process following all steps carefully if the first attempt is unsuccessful. 

Channels

The following table summarises the channels available for the ZEN24 Z-Wave Plus Toggle Dimmer Light Switch Ver 2.0.

Channel Channel Id Channel Type UID Category Item Type
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer

Dimmer

Restore Last Value

Restore Last Dimming level on ON.

Property Value      
Configuration ID config_restoreLastValue      
Data Type BOOLEAN   Default Value true
Options Restore Last Value (true)      
  Restore Full Brightness (false)      

Device Configuration

The following table provides a summary of the configuration parameters available in the ZEN24 Z-Wave Plus Toggle Dimmer Light Switch Ver 2.0. Detailed information on each parameter can be found below.

Parameter Description
1: Toggle Control Controls behavior of the toggle switch
1: Lifeline  

1: Toggle Control

Controls behavior of the toggle switch

Overview

Choose if you want the to turn the light on by clicking the toggle up or down Values:

0 – Toggle up turns the light on, toggle down turns the light off (default);

1 – Toggle up turns the light off, toggle down turns the light on

Property Value
Configuration ID config_1_1
Data Type INTEGER
Range 0 to 1
Default Value 0

1: Lifeline

Overview

Once the Z-Wave switch is added to your network, you are able to turn the device on or off and adjust brightness remotely from your mobile device, computer, or Z-Wave remote control. Depending on your Z-Wave gateway’s home automation software capabilities, you may be able to associate your ZWave switch in groups with other ZWave devices to schedule scenes and create events. This toggle dimmer switch supports Group 1 with up to 5 devices for lifeline communication. This device will send MULTILEVEL REPORT to Group 1 when operated manually. Please refer to your controller’s user guide for advanced programming instructions as they are a little different for each software.

Property Value
Configuration ID group_1
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.