KFOB 4 button keyfob

This describes the Z-Wave device KFOB, manufactured by Z-Wave.Me with the thing type UID of zwaveme_kfob_00_000.

4 button keyfob

Channels

The following table summarises the channels available for the KFOB 4 button keyfob.

Channel Channel Id Channel Type UID Category Item Type
Scene Number scene_number scene_number   Number
  battery-level system.battery-level    

Device Configuration

The following table provides a summary of the configuration parameters available in the KFOB 4 button keyfob. Detailed information on each parameter can be found below.

Parameter Description
1: Button 1 and 3 pair mode In separate mode button 1 works with group 1, button 3 with groups 3. Click is On, Hold is…
2: Button 2 and 4 pair mode In separate mode button 1 works with group 2, button 4 with groups 3. Click is On, Hold is…
11: Action on group 1 In Switch On/Off only mode On command is sent on Dim Up, Off on Dim Down. In Scenes mode t…
12: Action on group 2 In Switch On/Off only mode On command is sent on Dim Up, Off on Dim Down. In Scenes mode t…
13: Action on group 3 In Switch On/Off only mode On command is sent on Dim Up, Off on Dim Down. In Scenes mode t…
14: Action on group 4 In Switch On/Off only mode On command is sent on Dim Up, Off on Dim Down. In Scenes mode t…
20: Typical click timeout Typical time used to differenciate click, hold and double clicks in 10ms units
21: Send the following Switch All commands  
22: Invert buttons  
24: LED confirmation mode  
30: Send unsolicited Battery Report on Wake Up  
1: Controlled by button 1 or single clicks of buttons 1 and 3  
2: Controlled by button 3 or double clicks of buttons 1 and 3  
3: Controlled by button 2 or single clicks of buttons 2 and 4  
4: Controlled by button 4 or double clicks of buttons 2 and 4  

1: Button 1 and 3 pair mode

In separate mode button 1 works with group 1, button 3 with groups 3. Click is On, Hold is dimming Up, Double click is Off, Click-Hold is dimming Down. In pair button 1/3 are Up/Down correspondingly. Click is On/Off, Hold is dimming Up/Down. Single clicks

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 1
Options Separately (0)      
  In pair without double clicks (1)      
  In pair with double clicks (2)      

2: Button 2 and 4 pair mode

In separate mode button 1 works with group 2, button 4 with groups 3. Click is On, Hold is dimming Up, Double click is Off, Click-Hold is dimming Down. In pair button 2/4 are Up/Down correspondingly. Click is On/Off, Hold is dimming Up/Down. Single clicks

Property Value      
Configuration ID config_2_1      
Data Type INTEGER   Default Value 1
Options Separately (0)      
  In pair without double clicks (1)      
  In pair with double clicks (2)      

11: Action on group 1

In Switch On/Off only mode On command is sent on Dim Up, Off on Dim Down. In Scenes mode the scene ID sent is (10 * group + ActionID), where ActionID is: 1 = On, 2 = Off, 3 = Dim Up Start, 4 = Dim Down Start, 5 = Dim Up Stop, 6 = Dim Down Stop

Property Value      
Configuration ID config_11_1      
Data Type INTEGER   Default Value 1
Options Disabled (0)      
  Switch On/Off and Dim (send Basic Set and Switch Multilevel) (1)      
  Switch On/Off only (send Basic Set) (2)      
  Switch all (3)      
  Send Scenes (4)      
  Send Preconfigured Scenes (5)      
  Control devices in proximity (6)      

12: Action on group 2

In Switch On/Off only mode On command is sent on Dim Up, Off on Dim Down. In Scenes mode the scene ID sent is (10 * group + ActionID), where ActionID is: 1 = On, 2 = Off, 3 = Dim Up Start, 4 = Dim Down Start, 5 = Dim Up Stop, 6 = Dim Down Stop

Property Value      
Configuration ID config_12_1      
Data Type INTEGER   Default Value 1
Options Disabled (0)      
  Switch On/Off and Dim (send Basic Set and Switch Multilevel) (1)      
  Switch On/Off only (send Basic Set) (2)      
  Switch all (3)      
  Send Scenes (4)      
  Send Preconfigured Scenes (5)      
  Control devices in proximity (6)      

13: Action on group 3

In Switch On/Off only mode On command is sent on Dim Up, Off on Dim Down. In Scenes mode the scene ID sent is (10 * group + ActionID), where ActionID is: 1 = On, 2 = Off, 3 = Dim Up Start, 4 = Dim Down Start, 5 = Dim Up Stop, 6 = Dim Down Stop

Property Value      
Configuration ID config_13_1      
Data Type INTEGER   Default Value 1
Options Disabled (0)      
  Switch On/Off and Dim (send Basic Set and Switch Multilevel) (1)      
  Switch On/Off only (send Basic Set) (2)      
  Switch all (3)      
  Send Scenes (4)      
  Send Preconfigured Scenes (5)      
  Control devices in proximity (6)      

14: Action on group 4

In Switch On/Off only mode On command is sent on Dim Up, Off on Dim Down. In Scenes mode the scene ID sent is (10 * group + ActionID), where ActionID is: 1 = On, 2 = Off, 3 = Dim Up Start, 4 = Dim Down Start, 5 = Dim Up Stop, 6 = Dim Down Stop

Property Value      
Configuration ID config_14_1      
Data Type INTEGER   Default Value 1
Options Disabled (0)      
  Switch On/Off and Dim (send Basic Set and Switch Multilevel) (1)      
  Switch On/Off only (send Basic Set) (2)      
  Switch all (3)      
  Send Scenes (4)      
  Send Preconfigured Scenes (5)      
  Control devices in proximity (6)      

20: Typical click timeout

Typical time used to differenciate click, hold and double clicks in 10ms units

Property Value
Configuration ID config_20_1
Data Type INTEGER
Range 0 to 255
Default Value 50

21: Send the following Switch All commands

Property Value      
Configuration ID config_21_1      
Data Type INTEGER   Default Value 1
Options Switch all on and off (-1)      
  NO (Normal Open) (1)      
  NC (Normal Close) (2)      

22: Invert buttons

Property Value      
Configuration ID config_22_1      
Data Type INTEGER   Default Value 0
Options No (0)      
  Yes (1)      

24: LED confirmation mode

Property Value      
Configuration ID config_24_1      
Data Type INTEGER   Default Value 2
Options No confirmations (0)      
  Confirm button press (1)      
  Confirm button press and delivery (2)      

30: Send unsolicited Battery Report on Wake Up

Property Value      
Configuration ID config_30_1      
Data Type INTEGER   Default Value 0
Options No (0)      
  To same node as wake up notification (1)      
  Broadcast to neighbours (2)      

1: Controlled by button 1 or single clicks of buttons 1 and 3

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Controlled by button 3 or double clicks of buttons 1 and 3

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Controlled by button 2 or single clicks of buttons 2 and 4

Property Value
Configuration ID group_3
Data Type TEXT
Range to

4: Controlled by button 4 or double clicks of buttons 2 and 4

Property Value
Configuration ID group_4
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.