WALLC-S Wall Controller

This describes the Z-Wave device WALLC-S, manufactured by Z-Wave.Me with the thing type UID of zwaveme_wallcs_00_000.

Wall Controller

Channels

The following table summarises the channels available for the WALLC-S Wall Controller.

Channel Channel Id Channel Type UID Category Item Type
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer
Scene Activation scene_number scene_number   Number
Scene Number scene_number scene_number   Number
  battery-level system.battery-level    

Dimmer

Restore Last Value

Restore Last Dimming level on ON.

Property Value      
Configuration ID config_restoreLastValue      
Data Type BOOLEAN   Default Value true
Options Restore Last Value (true)      
  Restore Full Brightness (false)      

Device Configuration

The following table provides a summary of the configuration parameters available in the WALLC-S Wall Controller. Detailed information on each parameter can be found below.

Parameter Description
1: Button 1 and 3 pair mode In separate mode button 1 works with group 1, button 3 with groups 3. Click is On, Hold is…
2: Button 2 and 4 pair mode In separate mode button 1 works with group 2, button 4 with groups 3. Click is On, Hold is…
11: Action on group 1 In Switch On/Off only mode On command is sent on Dim Up, Off on Dim Down. In Scenes mode t…
12: Action on group 2 In Switch On/Off only mode On command is sent on Dim Up, Off on Dim Down. In Scenes mode t…
13: Action on group 3 In Switch On/Off only mode On command is sent on Dim Up, Off on Dim Down. In Scenes mode t…
14: Action on group 4 In Switch On/Off only mode On command is sent on Dim Up, Off on Dim Down. In Scenes mode t…
21: Send the following Switch All commands  
22: Invert buttons  
25: Blocks wakeup even when wakeup interval is set If the device wakes up and there is no controller nearby, several unsuccessful communicati…
30: Send unsolicited Battery Report on Wake Up  
1: Lifeline  
2: Group 1  
3: Group 2  
4: Group 3  
5: Group 4  

1: Button 1 and 3 pair mode

In separate mode button 1 works with group 1, button 3 with groups 3. Click is On, Hold is dimming Up, Double click is Off, Click-Hold is dimming Down. In pair button 1/3 are Up/Down correspondingly. Click is On/Off, Hold is dimming Up/Down. Single clicks

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 1
Options Separately (0)      
  In pair without double clicks (1)      
  In pair with double clicks (2)      

2: Button 2 and 4 pair mode

In separate mode button 1 works with group 2, button 4 with groups 3. Click is On, Hold is dimming Up, Double click is Off, Click-Hold is dimming Down. In pair button 2/4 are Up/Down correspondingly. Click is On/Off, Hold is dimming Up/Down. Single clicks

Property Value      
Configuration ID config_2_1      
Data Type INTEGER   Default Value 1
Options Separately (0)      
  In pair without double clicks (1)      
  In pair with double clicks (2)      

11: Action on group 1

In Switch On/Off only mode On command is sent on Dim Up, Off on Dim Down. In Scenes mode the scene ID sent is (10 * group + ActionID), where ActionID is: 1 = On, 2 = Off, 3 = Dim Up Start, 4 = Dim Down Start, 5 = Dim Up Stop, 6 = Dim Down Stop

Property Value      
Configuration ID config_11_1      
Data Type INTEGER   Default Value 1
Options Disabled (0)      
  Switch On/Off and Dim (send Basic Set and Switch Multilevel) (1)      
  Switch On/Off only (send Basic Set) (2)      
  Switch all (3)      
  Send Scenes (4)      
  Send Preconfigured Scenes (5)      
  Control Door Lock (7)      
  Central Scene to Gateway (8)      

12: Action on group 2

In Switch On/Off only mode On command is sent on Dim Up, Off on Dim Down. In Scenes mode the scene ID sent is (10 * group + ActionID), where ActionID is: 1 = On, 2 = Off, 3 = Dim Up Start, 4 = Dim Down Start, 5 = Dim Up Stop, 6 = Dim Down Stop

Property Value      
Configuration ID config_12_1      
Data Type INTEGER   Default Value 1
Options Disabled (0)      
  Switch On/Off and Dim (send Basic Set and Switch Multilevel) (1)      
  Switch On/Off only (send Basic Set) (2)      
  Switch all (3)      
  Send Scenes (4)      
  Send Preconfigured Scenes (5)      
  Control Door Lock (7)      
  Central Scene to Gateway (8)      

13: Action on group 3

In Switch On/Off only mode On command is sent on Dim Up, Off on Dim Down. In Scenes mode the scene ID sent is (10 * group + ActionID), where ActionID is: 1 = On, 2 = Off, 3 = Dim Up Start, 4 = Dim Down Start, 5 = Dim Up Stop, 6 = Dim Down Stop

Property Value      
Configuration ID config_13_1      
Data Type INTEGER   Default Value 1
Options Disabled (0)      
  Switch On/Off and Dim (send Basic Set and Switch Multilevel) (1)      
  Switch On/Off only (send Basic Set) (2)      
  Switch all (3)      
  Send Scenes (4)      
  Send Preconfigured Scenes (5)      
  Control Door Lock (7)      
  Central Scene to Gateway (8)      

14: Action on group 4

In Switch On/Off only mode On command is sent on Dim Up, Off on Dim Down. In Scenes mode the scene ID sent is (10 * group + ActionID), where ActionID is: 1 = On, 2 = Off, 3 = Dim Up Start, 4 = Dim Down Start, 5 = Dim Up Stop, 6 = Dim Down Stop

Property Value      
Configuration ID config_14_1      
Data Type INTEGER   Default Value 1
Options Disabled (0)      
  Switch On/Off and Dim (send Basic Set and Switch Multilevel) (1)      
  Switch On/Off only (send Basic Set) (2)      
  Switch all (3)      
  Send Scenes (4)      
  Send Preconfigured Scenes (5)      
  Control Door Lock (7)      
  Central Scene to Gateway (8)      

21: Send the following Switch All commands

Property Value      
Configuration ID config_21_1      
Data Type INTEGER   Default Value 1
Options NO (Normal Open) (1)      
  NC (Normal Close) (2)      
  Switch all on and off (255)      

22: Invert buttons

Property Value      
Configuration ID config_22_1      
Data Type INTEGER   Default Value 0
Options No (0)      
  Yes (1)      

25: Blocks wakeup even when wakeup interval is set

If the device wakes up and there is no controller nearby, several unsuccessful communication attempts will drain battery.

Property Value      
Configuration ID config_25_1      
Data Type INTEGER   Default Value 0
Options Wakeup is blocked (0)      
  Wakeup is possible (1)      

30: Send unsolicited Battery Report on Wake Up

Property Value      
Configuration ID config_30_1      
Data Type INTEGER   Default Value 0
Options No (0)      
  To same node as wake up notification (1)      
  Broadcast to neighbours (2)      

1: Lifeline

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Group 1

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Group 2

Property Value
Configuration ID group_3
Data Type TEXT
Range to

4: Group 3

Property Value
Configuration ID group_4
Data Type TEXT
Range to

5: Group 4

Property Value
Configuration ID group_5
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.