WCD2 Double Paddle Wall Controller

This describes the Z-Wave device WCD2, manufactured by Z-Wave.Me with the thing type UID of zwaveme_wcd2_00_000.

Double Paddle Wall Controller

Channels

The following table summarises the channels available for the WCD2 Double Paddle Wall Controller.

Channel Channel Id Channel Type UID Category Item Type
Scene Number scene_number scene_number   Number
  battery-level system.battery-level    

Device Configuration

The following table provides a summary of the configuration parameters available in the WCD2 Double Paddle Wall Controller. Detailed information on each parameter can be found below.

Parameter Description
1: Button 1 and 3 pair mode In separate mode button 1 works with group 1, button 3 with groups 3. Click is On, Hold is…
2: Button 2 and 4 pair mode In separate mode button 1 works with group 2, button 4 with groups 3. Click is On, Hold is…
11: Action on group 1 In Switch On/Off only mode On command is sent on Dim Up, Off on Dim Down. In Scenes mode t…
12: Action on group 2 In Switch On/Off only mode On command is sent on Dim Up, Off on Dim Down. In Scenes mode t…
13: Action on group 3 In Switch On/Off only mode On command is sent on Dim Up, Off on Dim Down. In Scenes mode t…
14: Action on group 4 In Switch On/Off only mode On command is sent on Dim Up, Off on Dim Down. In Scenes mode t…
20: Typical click timeout Typical time used to differentiate click, hold and double clicks in 10ms units
21: Send the following Switch All commands  
22: Invert buttons  
24: Led Confirmation Mode This allows to save battery
30: Send unsolicited Battery Report on Wake Up  
1: Group 1  
2: Group 2  
3: Group 3  
4: Group 4  

1: Button 1 and 3 pair mode

In separate mode button 1 works with group 1, button 3 with groups 3. Click is On, Hold is dimming Up, Double click is Off, Click-Hold is dimming Down. In pair button 1/3 are Up/Down correspondingly. Click is On/Off, Hold is dimming Up/Down. Single clicks

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 1
Options Separately (0)      
  In pair without double clicks (1)      
  In pair with double clicks (2)      

2: Button 2 and 4 pair mode

In separate mode button 1 works with group 2, button 4 with groups 3. Click is On, Hold is dimming Up, Double click is Off, Click-Hold is dimming Down. In pair button 2/4 are Up/Down correspondingly. Click is On/Off, Hold is dimming Up/Down. Single clicks

Property Value      
Configuration ID config_2_1      
Data Type INTEGER   Default Value 1
Options Separately (0)      
  In pair without double clicks (1)      
  In pair with double clicks (2)      

11: Action on group 1

In Switch On/Off only mode On command is sent on Dim Up, Off on Dim Down. In Scenes mode the scene ID sent is (10 * group + ActionID), where ActionID is: 1 = On, 2 = Off, 3 = Dim Up Start, 4 = Dim Down Start, 5 = Dim Up Stop, 6 = Dim Down Stop

Property Value      
Configuration ID config_11_1      
Data Type INTEGER   Default Value 1
Options Disabled (0)      
  Switch On/Off and Dim (send Basic Set and Switch Multilevel) (1)      
  Switch On/Off only (send Basic Set) (2)      
  Switch all (3)      
  Send Scenes (4)      
  Send Preconfigured Scenes (5)      

12: Action on group 2

In Switch On/Off only mode On command is sent on Dim Up, Off on Dim Down. In Scenes mode the scene ID sent is (10 * group + ActionID), where ActionID is: 1 = On, 2 = Off, 3 = Dim Up Start, 4 = Dim Down Start, 5 = Dim Up Stop, 6 = Dim Down Stop

Property Value      
Configuration ID config_12_1      
Data Type INTEGER   Default Value 1
Options Disabled (0)      
  Switch On/Off and Dim (send Basic Set and Switch Multilevel) (1)      
  Switch On/Off only (send Basic Set) (2)      
  Switch all (3)      
  Send Scenes (4)      
  Send Preconfigured Scenes (5)      

13: Action on group 3

In Switch On/Off only mode On command is sent on Dim Up, Off on Dim Down. In Scenes mode the scene ID sent is (10 * group + ActionID), where ActionID is: 1 = On, 2 = Off, 3 = Dim Up Start, 4 = Dim Down Start, 5 = Dim Up Stop, 6 = Dim Down Stop

Property Value      
Configuration ID config_13_1      
Data Type INTEGER   Default Value 1
Options Disabled (0)      
  Switch On/Off and Dim (send Basic Set and Switch Multilevel) (1)      
  Switch On/Off only (send Basic Set) (2)      
  Switch all (3)      
  Send Scenes (4)      
  Send Preconfigured Scenes (5)      

14: Action on group 4

In Switch On/Off only mode On command is sent on Dim Up, Off on Dim Down. In Scenes mode the scene ID sent is (10 * group + ActionID), where ActionID is: 1 = On, 2 = Off, 3 = Dim Up Start, 4 = Dim Down Start, 5 = Dim Up Stop, 6 = Dim Down Stop

Property Value      
Configuration ID config_14_1      
Data Type INTEGER   Default Value 1
Options Disabled (0)      
  Switch On/Off and Dim (send Basic Set and Switch Multilevel) (1)      
  Switch On/Off only (send Basic Set) (2)      
  Switch all (3)      
  Send Scenes (4)      
  Send Preconfigured Scenes (5)      

20: Typical click timeout

Typical time used to differentiate click, hold and double clicks in 10ms units

Property Value
Configuration ID config_20_1
Data Type INTEGER
Range 0 to 255
Default Value 50

21: Send the following Switch All commands

Property Value      
Configuration ID config_21_1      
Data Type INTEGER   Default Value 1
Options NO (Normal Open) (1)      
  NC (Normal Close) (2)      
  Switch all on and off (255)      

22: Invert buttons

Property Value      
Configuration ID config_22_1      
Data Type INTEGER   Default Value 0
Options No (0)      
  Yes (1)      

24: Led Confirmation Mode

This allows to save battery

Property Value      
Configuration ID config_24_1      
Data Type INTEGER   Default Value 0
Options No Confirmations (0)      
  Confirm Button Press (1)      
  Confirm Button Press and delivery (2)      

30: Send unsolicited Battery Report on Wake Up

Property Value      
Configuration ID config_30_1      
Data Type INTEGER   Default Value 0
Options No (0)      
  To same node as wake up notification (1)      
  Broadcast to neighbours (2)      

1: Group 1

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Group 2

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Group 3

Property Value
Configuration ID group_3
Data Type TEXT
Range to

4: Group 4

Property Value
Configuration ID group_4
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.