ZME_05433 Zwave.Me Dimmer Set Everlux

This describes the Z-Wave device ZME_05433, manufactured by Z-Wave.Me with the thing type UID of zwaveme_zme05433_00_000.

Zwave.Me Dimmer Set Everlux

Channels

The following table summarises the channels available for the ZME_05433 Zwave.Me Dimmer Set Everlux.

Channel Channel Id Channel Type UID Category Item Type
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer
Scene Number scene_number scene_number   Number

Dimmer

Restore Last Value

Restore Last Dimming level on ON.

Property Value      
Configuration ID config_restoreLastValue      
Data Type BOOLEAN   Default Value true
Options Restore Last Value (true)      
  Restore Full Brightness (false)      

Device Configuration

The following table provides a summary of the configuration parameters available in the ZME_05433 Zwave.Me Dimmer Set Everlux. Detailed information on each parameter can be found below.

Parameter Description
1: LED mode Set LED indication mode
2: Automatically switch off after If not zero, automatically switch off after a user defined time
3: What to do on RF off command Defines how to interpret RF Off command.
4: Ignore start level ignore start level in StartLevelChange
5: Dimming speed Time to dim on button presses
6: Dimming long speed Time to dim on button holds and StartLevelChange
7: Set maximum light level on On click set action on ON command
1: Association group 1 Single press and hold of up/down buttons (max. nodes in group: 14)
2: Association group 2  
3: Association group 3 Send Reports on blind state change

1: LED mode

Set LED indication mode

Overview

Set LED indication mode

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 3
Options Disabled (0)      
  Show switch state (1)      
  Night mode (inverted switch state) (2)      
  Operated by Indicator Command Class (Default) (3)      

2: Automatically switch off after

If not zero, automatically switch off after a user defined time

Overview

Automatically switch off after: 0 Disabled (Default); 1 — 65535 sec

Property Value      
Configuration ID config_2_2      
Data Type INTEGER   Default Value 0
Options Disabled (Default) (0)      
  Sec (1)      

3: What to do on RF off command

Defines how to interpret RF Off command.

Overview

Defines how to interpret RF Off command. Can be used in conjunction with Auto Off function: Ignore - to switch on the light by motion detectors and switch it off after some amount of time: in case of multiple motion detectors each would try to switch the light off that would break logics; Switch on - to switch on the light on both On and Off paddle press on the remote and switch it off after some amount of time. Button off click will still work (if button operations are not disabled).

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 0
Options Switch off (Default) (0)      
  Ignore (1)      
  Switch on (2)      
  Switch on if load is off else switch off (3)      

4: Ignore start level

ignore start level in StartLevelChange

Overview

Defines if the dimmer shall ignore start level in StartLevelChange command despite it is specified or not

Property Value      
Configuration ID config_4_1      
Data Type INTEGER   Default Value 1
Options No (0)      
  Yes (Default) (1)      

5: Dimming speed

Time to dim on button presses

Overview

Time to dim on button presses and Set command (if it has no duration specified). If not 0, dimming will be done smoothly to preserv bulb life.

Property Value      
Configuration ID config_5_1      
Data Type INTEGER      
Range 0 to 255   Default Value 30
Options Instantly (0)      
  Default (30)      

6: Dimming long speed

Time to dim on button holds and StartLevelChange

Overview

Time to dim on button holds and StartLevelChange command (if it has no duration specified).

Property Value
Configuration ID config_6_1
Data Type INTEGER
Range 1 to 255
Default Value 3

7: Set maximum light level on On click

set action on ON command

Overview

Defines if the dimmer shall set maximum light level on On command. By default on On command dimmer restores last level. This parameter allows to configure to set maximum level on second On command (if already On) or to always switch on to maximum level

Property Value      
Configuration ID config_7_1      
Data Type INTEGER   Default Value 0
Options No (Default) (0)      
  If already On (1)      
  Always (2)      

1: Association group 1

Single press and hold of up/down buttons (max. nodes in group: 14)

Overview

Association group 1: Single press and hold of up/down buttons (max. nodes in group: 14)

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Association group 2

Overview

Double press and press-hold of up/down buttons (max. nodes in group: 14)

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Association group 3

Send Reports on blind state change

Overview

Send Reports on blind state change (max. nodes in group: 14)

Property Value
Configuration ID group_3
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.