ZME_05459 Blinds controller

This describes the Z-Wave device ZME_05459, manufactured by Z-Wave.Me with the thing type UID of zwaveme_zme05459_00_000.

Blinds controller

Channels

The following table summarises the channels available for the ZME_05459 Blinds controller.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Blinds control blinds_control blinds_control Blinds Rollershutter

Blinds control

Invert control

Invert the blinds control

Property Value      
Configuration ID config_invert_control      
Data Type BOOLEAN   Default Value false
Options Yes (true)      
  No (false)      

Invert percentage value

Invert the blinds percentage value

Property Value      
Configuration ID config_invert_percent      
Data Type BOOLEAN   Default Value false
Options Yes (true)      
  No (false)      

Step duration

Sets the dim rate speed
Values from 1 to 127 are defined in seconds, while values from 128 to 254 are defined in minutes.

Property Value      
Configuration ID config_duration      
Data Type INTEGER      
Range 1 to 254   Default Value 255
Options Device Default (255)      
  Change Instantly (0)      

Device Configuration

The following table provides a summary of the configuration parameters available in the ZME_05459 Blinds controller. Detailed information on each parameter can be found below.

Parameter Description
1: LED mode Set LED indication mode
2: Automatically open or close after Automatically open or close blind after time
3: What to do on RF close command Defines how to interpret RF Off command.
4: Full close time Time in seconds to go from opened to closed state.
5: Full open time Time in seconds to go from closed to open state.
6: Node ID of the blocking device Id of the device which can block the blinds
7: On which command from blocking node to enable the protection Defines which command from blocking device to interpret as closed door and hence, unprotec…
8: Stop or Revert if opposite button is pressed Defines behaviour on open press while closing and vice versa.
9: Invert open and close relays Allows exchanging open and close relays if blind control is wired to the motor incorrectly
10: Typical click timeout Typical time used to differentiate click, hold and double and triple clicks in 10ms units
11: Invert buttons Allows exchanging the functionality of the buttons
12: Switch by buttons Local operations by buttons will/will not/ switch the load
13: Action on button single press or hold Defines which command should be sent on button single press or hold.
14: Action on button double press or hold Defines which command should be sent on button double press or press-hold.
15: Send the following Switch All commands Defines what to do when a Switch All command arrives.
16: What to do on button Down press Defines how to interpret button Down press. Depends on ‘Switch by buttons’ parameter.
17: Action on Auto open or close function Defines the action to perform upon auto open or auto close.
1: Single press and hold of up/down buttons  
2: Double press and press-hold of up/down buttons  
3: Send Reports on blind state change  

1: LED mode

Set LED indication mode

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 3
Options Disabled (0)      
  Show working state (1)      
  Show idle state (2)      
  Operated by Indicator Command Class (3)      
  Show if not closed (4)      

2: Automatically open or close after

Automatically open or close blind after time

Overview

If not zero, automatically open or close blind after a user defined time

Property Value      
Configuration ID config_2_2      
Data Type INTEGER      
Range 0 to 65535   Default Value 0
Options Disabled (0)      

3: What to do on RF close command

Defines how to interpret RF Off command.

Overview

Defines how to interpret RF Off command. Can be used in conjunction with Auto Close function: Ignore - to open the door by motion detectors and close it back after some amount of time: in case of multiple motion detectors each would try to open that would break logics; Open - to open on both On and Off paddle press on the remote and close after some amount of time. Button close click will still work (if button operations are not disabled). Note that Dim Down command will still begin close motion.

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 0
Options Close (0)      
  Ignore (1)      
  Open (2)      
  Open if closed else close (3)      

4: Full close time

Time in seconds to go from opened to closed state.

Overview

Time to go from opened to closed state. Used to estimate the current level. Note that in Permanent motion mode the reported value would a be Closed or Opened, while all Basic and Multilevel Set values (1-99, 255) would Open except 0 value that would Close.

Property Value      
Configuration ID config_4_1      
Data Type INTEGER      
Range 0 to 255   Default Value 60
Options Keep in permanent motion (0)      

5: Full open time

Time in seconds to go from closed to open state.

Overview

Time to go from closed to open state. This value may differ from Full close time for some blinds due to gravity. Used to estimate the current level. Note that in Permanent motion mode the reported value would a be Closed or Opened, while all Basic and Multilevel Set values (1-99, 255) would Open except 0 value that would Close.

Property Value      
Configuration ID config_5_1      
Data Type INTEGER      
Range 0 to 255   Default Value 60
Options Keep in permanent motion (0)      

6: Node ID of the blocking device

Id of the device which can block the blinds

Overview

Id of the device which commands would be interpreted not as Open/Close, but as block/unblock. Usefull with door opening detector: if the door is open, block the blind not to break shades while they move.

Property Value      
Configuration ID config_6_1      
Data Type INTEGER      
Range 0 to 232   Default Value 0
Options Disabled (0)      

7: On which command from blocking node to enable the protection

Defines which command from blocking device to interpret as closed door and hence, unprotected.

Property Value      
Configuration ID config_7_1      
Data Type INTEGER   Default Value 0
Options on On (0)      
  on Off (1)      

8: Stop or Revert if opposite button is pressed

Defines behaviour on open press while closing and vice versa.

Overview

Defines behaviour on open press while closing and vice versa. To allow Stop behavior when switched by remote, use Stop by Basic

Property Value      
Configuration ID config_8_1      
Data Type INTEGER   Default Value 0
Options Stop (by buttons and Binary) (0)      
  Revert (1)      
  Stop (by buttons, Binary and Basic) (2)      

9: Invert open and close relays

Allows exchanging open and close relays if blind control is wired to the motor incorrectly

Property Value      
Configuration ID config_9_1      
Data Type INTEGER   Default Value 0
Options No (0)      
  Yes (1)      

10: Typical click timeout

Typical time used to differentiate click, hold and double and triple clicks in 10ms units

Property Value
Configuration ID config_10_1
Data Type INTEGER
Range 0 to 100
Default Value 50

11: Invert buttons

Allows exchanging the functionality of the buttons

Property Value      
Configuration ID config_11_1      
Data Type INTEGER   Default Value 0
Options No (0)      
  Yes (1)      

12: Switch by buttons

Local operations by buttons will/will not/ switch the load

Overview

If disabled, the local operations by buttons will not switch the load, but only send commands to On/Off association group. In this mode buttons are not linked with the switch anymore. They can be used separately: buttons to control remote device, switch will operate by RF commands only.

Property Value      
Configuration ID config_12_1      
Data Type INTEGER   Default Value 1
Options No (0)      
  By single press and hold (1)      
  By double press and hold (2)      

13: Action on button single press or hold

Defines which command should be sent on button single press or hold.

Overview

Defines which command should be sent on button single press or hold. Basic and Scene Activation commands are sent to Association group. Use Scene Controller Conf to set up Scene ID for Scene Activation. Switch All commands are sent broadcast.

Property Value      
Configuration ID config_13_1      
Data Type INTEGER   Default Value 4
Options Disabled (0)      
  Switch On/Off (send Basic Set) (1)      
  Switch All (2)      
  Send Scenes (3)      
  Switch On/Off and Dim (send Basic Set and Switch Multilevel) (4)      
  Send Preconfigured Scenes (5)      

14: Action on button double press or hold

Defines which command should be sent on button double press or press-hold.

Overview

Defines which command should be sent on button double press or press-hold. Basic and Scene Activation commands are sent to Association group. Use Scene Controller Conf to set up Scene ID for Scene Activation. Switch All commands are sent broadcast. If not disabled, the device will wait for a click timeout to see if the second click would be pressed. This will introduce a small delay for single click commands

Property Value      
Configuration ID config_14_1      
Data Type INTEGER   Default Value 0
Options Disabled (0)      
  Switch On/Off (send Basic Set) (1)      
  Switch All (2)      
  Send Scenes (3)      
  Switch On/Off and Dim (send Basic Set and Switch Multilevel) (4)      
  Send Preconfigured Scenes (5)      

15: Send the following Switch All commands

Defines what to do when a Switch All command arrives.

Property Value      
Configuration ID config_15_1      
Data Type INTEGER   Default Value 1
Options Switch off only (1)      
  Switch on only (2)      
  Switch all on and off (255)      

16: What to do on button Down press

Defines how to interpret button Down press. Depends on ‘Switch by buttons’ parameter.

Overview

Defines how to interpret button Down press. Depends on “Switch by buttons” parameter. If not Disabled this parameter will affect the action selected by the latter parameter. Can be used in conjunction with Auto Off function.

Property Value      
Configuration ID config_16_1      
Data Type INTEGER   Default Value 0
Options Close (0)      
  Open if closed else close (1)      
  Open (2)      

17: Action on Auto open or close function

Defines the action to perform upon auto open or auto close.

Property Value      
Configuration ID config_17_1      
Data Type INTEGER   Default Value 0
Options Close blinds (0)      
  Open blinds (1)      

1: Single press and hold of up/down buttons

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Double press and press-hold of up/down buttons

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Send Reports on blind state change

Property Value
Configuration ID group_3
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.