ZME_05461 Double switch

This describes the Z-Wave device ZME_05461, manufactured by Z-Wave.Me with the thing type UID of zwaveme_zme05461_00_000.

Double switch

Channels

The following table summarises the channels available for the ZME_05461 Double switch.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number
Switch 1 switch_binary1 switch_binary Switch Switch
Electric meter (kWh) 1 meter_kwh1 meter_kwh Energy Number
Electric meter (watts) 1 meter_watts1 meter_watts Energy Number
Switch 2 switch_binary2 switch_binary Switch Switch
Electric meter (kWh) 2 meter_kwh2 meter_kwh Energy Number
Electric meter (watts) 2 meter_watts2 meter_watts Energy Number

Device Configuration

The following table provides a summary of the configuration parameters available in the ZME_05461 Double switch. Detailed information on each parameter can be found below.

Parameter Description
1: Set LED indication mode  
2: Automatically switch off first channel after If not zero, automatically switch off after a user defined time
3: Function of RF off command on first channel Defines how to interpret RF first channel Off command. Can be used in conjunction with Aut…
4: Switch on/off by holding buttons Defines if the switch should change it state to on/off if buttons are being hold.
5: Restore switch state after power cycle Defines if the switch should restore switch state to the last state prior to device power …
11: Invert buttons Allows for exchanging ON and OFF.
12: Switch by buttons (first channel) If disabled, the local operations by buttons will not switch relay on first channel, but o…
13: Action on button single press or hold Defines which command should be sent on button single press or hold. Basic and Scene Activ…
14: Action on button double press or hold Defines which command should be sent on button single press or hold. Basic and Scene Activ…
16: What to do on button Down press (for both channels) Defines how to interpret button Down press. Depends on parameters 12 and 32 ‘Switch by but…
20: Energy consumption for first channel Specify the consumption of the load in watts, for the calculation of power consumption. Ma…
22: Automatically switch off second channel after If not zero, automatically switch off after a user defined time
23: Function of RF off command on second channel Defines how to interpret RF second channel Off command. Can be used in conjunction with Au…
32: Switch by buttons (second channel) If disabled, the local operations by buttons will not switch relay on second channel, but …
40: Energy consumption for second channel Specify the consumption of the load in watts, for the calculation of power consumption. Ma…
1: Group 1  
2: Group 2  
3: Group 3  

1: Set LED indication mode

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 1
Options Disabled (0)      
  Show switch state (1)      
  night light (inverted state) (2)      

2: Automatically switch off first channel after

If not zero, automatically switch off after a user defined time

Property Value
Configuration ID config_2_2
Data Type INTEGER
Range 0 to 65535
Default Value 0

3: Function of RF off command on first channel

Defines how to interpret RF first channel Off command. Can be used in conjunction with Auto Off function: Ignore - to switch on the light by motion detectors and switch it off after some amount of time: in case of multiple motion detectors each would try

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 0
Options Switch OFF (0)      
  Ignore (1)      
  Switch ON (2)      
  Switch on if load is off else switch off (3)      

4: Switch on/off by holding buttons

Defines if the switch should change it state to on/off if buttons are being hold.

Property Value      
Configuration ID config_4_1      
Data Type INTEGER   Default Value 1
Options No (0)      
  Yes (only for the first channel) (1)      
  Yes (only for the second channel) (2)      
  Yes (for both channels) (3)      

5: Restore switch state after power cycle

Defines if the switch should restore switch state to the last state prior to device power off (power cycle).

Property Value      
Configuration ID config_5_1      
Data Type INTEGER   Default Value 1
Options No, turn off (0)      
  Yes (only for the first channel) (1)      
  Yes (only for the second channel) (2)      
  Yes (for both channels) (3)      

11: Invert buttons

Allows for exchanging ON and OFF.

Property Value      
Configuration ID config_11_1      
Data Type INTEGER   Default Value 0
Options No (0)      
  Yes (1)      

12: Switch by buttons (first channel)

If disabled, the local operations by buttons will not switch relay on first channel, but only send commands to On/Off association group. In this mode buttons are not linked with the switch anymore. They can be used separately: buttons to control remote de

Property Value      
Configuration ID config_12_1      
Data Type INTEGER   Default Value 1
Options No (0)      
  By single press and hold (1)      
  By double press and press-hold (2)      

13: Action on button single press or hold

Defines which command should be sent on button single press or hold. Basic and Scene Activation commands are sent to Association group. Use Scene Controller Conf to set up Scene ID for Scene Activation. Switch All commands are sent broadcast.

Property Value      
Configuration ID config_13_1      
Data Type INTEGER   Default Value 2
Options Disabled (0)      
  Switch On/Off only (send Basic Set) (1)      
  Switch On/Off and Dim (send Basic Set and Switch Multilevel) (2)      
  Scene activation (3)      

14: Action on button double press or hold

Defines which command should be sent on button single press or hold. Basic and Scene Activation commands are sent to Association group. Use Scene Controller Conf to set up Scene ID for Scene Activation. Switch All commands are sent broadcast.

Property Value      
Configuration ID config_14_1      
Data Type INTEGER   Default Value 2
Options Disabled (0)      
  Switch On/Off only (send Basic Set) (1)      
  Switch On/Off and Dim (send Basic Set and Switch Multilevel) (2)      
  Scene activation (3)      

16: What to do on button Down press (for both channels)

Defines how to interpret button Down press. Depends on parameters 12 and 32 ‘Switch by buttons’ parameter. If not Disabled this parameter will affect the action selected by the latter parameter. Can be used in conjunction with Auto Off function.

Property Value      
Configuration ID config_16_1      
Data Type INTEGER   Default Value 1
Options Switch off (0)      
  Switch On if load is Off, else switch Off (1)      
  Switch on (2)      

20: Energy consumption for first channel

Specify the consumption of the load in watts, for the calculation of power consumption. Max load 1800 W.

Property Value      
Configuration ID config_20_2      
Data Type INTEGER   Default Value 0
Options Disabled (0)      

22: Automatically switch off second channel after

If not zero, automatically switch off after a user defined time

Property Value
Configuration ID config_22_2
Data Type INTEGER
Range 0 to 65535
Default Value 0

23: Function of RF off command on second channel

Defines how to interpret RF second channel Off command. Can be used in conjunction with Auto Off function: Ignore - to switch on the light by motion detectors and switch it off after some amount of time: in case of multiple motion detectors each would try

Property Value      
Configuration ID config_23_1      
Data Type INTEGER   Default Value 0
Options Switch OFF (0)      
  Ignore (1)      
  Switch ON (2)      
  Switch on if load is off else switch off (3)      

32: Switch by buttons (second channel)

If disabled, the local operations by buttons will not switch relay on second channel, but only send commands to On/Off association group. In this mode buttons are not linked with the switch anymore. They can be used separately: buttons to control remote d

Property Value      
Configuration ID config_32_1      
Data Type INTEGER   Default Value 2
Options No (0)      
  By single press and hold (1)      
  By double press and press-hold (2)      

40: Energy consumption for second channel

Specify the consumption of the load in watts, for the calculation of power consumption. Max load 1800 W.

Property Value      
Configuration ID config_40_2      
Data Type INTEGER   Default Value 0
Options Disabled (0)      

1: Group 1

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Group 2

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: Group 3

Property Value
Configuration ID group_3
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.