ZME_06437 Wall Plug Switch

This describes the Z-Wave device ZME_06437, manufactured by Z-Wave.Me with the thing type UID of zwaveme_zme06437_00_000.

Wall Plug Switch

Channels

The following table summarises the channels available for the ZME_06437 Wall Plug Switch.

Channel Channel Id Channel Type UID Category Item Type
Switch switch_binary switch_binary Switch Switch
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number

Device Configuration

The following table provides a summary of the configuration parameters available in the ZME_06437 Wall Plug Switch. Detailed information on each parameter can be found below.

Parameter Description
1: Set LED indication mode  
2: Automatic switch off If not zero, automatically switch off after a user defined time
3: Function of RF off command Defines how to interpret RF Off command. Can be used in conjunction with Auto Off function…
5: Restore switch state after power cycle Defines if the switch should restore switch state to the last state prior to device power …
20: Energy consumption Specify the consumption of the load in watts, for the calculation of power consumption. Ma…
21: Off Color  
22: On Color  
1: Group 1  
2: Group 2  

1: Set LED indication mode

Property Value      
Configuration ID config_1_1      
Data Type INTEGER   Default Value 2
Options Disabled (0)      
  Show switch state (1)      
  Operated by Indicator Command Class (2)      

2: Automatic switch off

If not zero, automatically switch off after a user defined time

Property Value
Configuration ID config_2_2
Data Type INTEGER
Range 0 to 65535
Default Value 0

3: Function of RF off command

Defines how to interpret RF Off command. Can be used in conjunction with Auto Off function: Ignore - to switch on the light by motion detectors and switch it off after some amount of time: in case of multiple motion detectors each would try to switch the

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 0
Options Switch OFF (0)      
  Ignore (1)      
  Switch ON (2)      
  Switch on if load is off else switch off (3)      

5: Restore switch state after power cycle

Defines if the switch should restore switch state to the last state prior to device power off (power cycle).

Property Value      
Configuration ID config_5_1      
Data Type INTEGER   Default Value 1
Options No, turn off (0)      
  Yes (Default) (1)      

20: Energy consumption

Specify the consumption of the load in watts, for the calculation of power consumption. Max load 1800 W.

Property Value
Configuration ID config_20_2
Data Type INTEGER
Range 0 to 1800
Default Value 0

21: Off Color

Property Value      
Configuration ID config_21_1      
Data Type INTEGER   Default Value 0
Options Off (0)      
  Red (1)      
  Green (2)      
  Blue (3)      
  Yellow (4)      

22: On Color

Property Value      
Configuration ID config_22_1      
Data Type INTEGER   Default Value 3
Options Off (0)      
  Red (1)      
  Green (2)      
  Blue (3)      
  Yellow (4)      

1: Group 1

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Group 2

Property Value
Configuration ID group_2
Data Type TEXT
Range to