ZME_06443 Single Paddle Wall Controller

This describes the Z-Wave device ZME_06443, manufactured by Z-Wave.Me with the thing type UID of zwaveme_zme06443_00_000.

Single Paddle Wall Controller

Channels

The following table summarises the channels available for the ZME_06443 Single Paddle Wall Controller.

Channel Channel Id Channel Type UID Category Item Type
Scene Number scene_number scene_number   Number
  battery-level system.battery-level    

Device Configuration

The following table provides a summary of the configuration parameters available in the ZME_06443 Single Paddle Wall Controller. Detailed information on each parameter can be found below.

Parameter Description
10: Typical click timeout Typical time used to differentiate click
11: Invert buttons  
13: Action on button single press or hold Defines which command should be sent on button single press or hold.
14: Action on button double press or hold Defines which command should be sent on button double press or press-hold.
15: Send the following Switch All commands  
20: Send unsolicited Battery Report on Wake Up  
1: Single Press  
2: Double Press  

10: Typical click timeout

Typical time used to differentiate click

Overview

Typical time used to differentiate click, hold, double and triple clicks

Defined in 10ms ticks.

Property Value
Configuration ID config_10_1
Data Type INTEGER
Range 1 to 100
Default Value 50

11: Invert buttons

Property Value      
Configuration ID config_11_1      
Data Type INTEGER   Default Value 0
Options No (0)      
  Yes (1)      

13: Action on button single press or hold

Defines which command should be sent on button single press or hold.

Overview

Defines which command should be sent on button single press or hold.

Basic and Scene commands are sent to Association group.

Switch All commands are sent broadcast.

Scenes have following meaning: Up = 1, Down = 2, Dim Up = 3, Dim Down = 4, Dim Up Stop = 5

Property Value      
Configuration ID config_13_1      
Data Type INTEGER      
Range 0 to 255   Default Value 1
Options Disabled (0)      
  Switch On, Off and dim using Basic Set (1)      
  Switch All (2)      
  Scenes (3)      

14: Action on button double press or hold

Defines which command should be sent on button double press or press-hold.

Overview

Defines which command should be sent on button double press or press-hold.

Basic and Scene commands are sent to Association group.

Switch All commands are sent broadcast.

If not disabled, the device will wait for a click timeout to see if the second click

Property Value      
Configuration ID config_14_1      
Data Type INTEGER   Default Value 1
Options Disabled (0)      
  Switch On, Off and dim using Basic Set (1)      
  Switch All (2)      
  Scenes (3)      

15: Send the following Switch All commands

Property Value      
Configuration ID config_15_1      
Data Type INTEGER   Default Value 0
Options Switch OFF Only (1)      
  Switch ON Only (2)      
  Switch all on and off (255)      

20: Send unsolicited Battery Report on Wake Up

Property Value      
Configuration ID config_20_1      
Data Type INTEGER   Default Value 0
Options No (0)      
  To same node as wake up notification (1)      
  Broadcast to neighbours (2)      

1: Single Press

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Double Press

Property Value
Configuration ID group_2
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.