Channel Channel Id Channel Type UID Category Item Type
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number
Thermostat mode thermostat_mode zwaveme_zmeft_00_000_thermostat_mode Temperature Number
Setpoint (heating) thermostat_setpoint_heating thermostat_setpoint Temperature Number
Setpoint (furnace) thermostat_setpoint_furnace thermostat_setpoint Temperature Number

Sensor (temperature)

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Setpoint (heating)

Scale

Select the scale to use for setpoints.

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Setpoint (furnace)

Scale

Select the scale to use for setpoints.

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Device Configuration

The following table provides a summary of the configuration parameters available in the ZME_FT Floor Thermostat. Detailed information on each parameter can be found below.

Parameter Description
1: Boost Dry mode duration  
2: Button mode  
3: Basic mode  
4: Temperature control interval  
5: Maximum allowed temperature deviation  
6: Maximal allowed temperature In all modes the thermostat will switch off heating until temperature drops below this lim…
10: Typical click timeout Typical time used to differenciate click from hold
1: Group 1 Unsolicited notifications about thermostat mode and setpoint temperature changes

1: Boost Dry mode duration

Property Value
Configuration ID config_1_2
Data Type INTEGER
Range 0 to 1800
Default Value 1800

2: Button mode

Property Value      
Configuration ID config_2_1      
Data Type INTEGER   Default Value 0
Options Toggle Normal Heating / Off (0)      
  Toggle Normal Heating / Energy Save (1)      
  Toggle Boost Dry (2)      

3: Basic mode

Property Value      
Configuration ID config_3_1      
Data Type INTEGER   Default Value 0
Options Toggle Normal Heating / Off (0)      
  Toggle Normal Heating / Energy Save (1)      
  Toggle Boost Dry (2)      
  Set Normal Heating set point temperature (in 0.1 C units) (3)      
  Switch on/off relay directly (only if Thermostat Mode is in Off state) (4)      

4: Temperature control interval

Property Value
Configuration ID config_4_1
Data Type INTEGER
Range 1 to 60
Default Value 18

5: Maximum allowed temperature deviation

Property Value
Configuration ID config_5_1
Data Type INTEGER
Range 1 to 60
Default Value 30

6: Maximal allowed temperature

In all modes the thermostat will switch off heating until temperature drops below this limit. For wooden and laminate floor maximal allowed temperature is 27 degree. For tile and concrete floor maximal allowed temperature value is 45 degree.

Property Value
Configuration ID config_6_1
Data Type INTEGER
Range 20 to 55
Default Value 27

10: Typical click timeout

Typical time used to differenciate click from hold

Property Value
Configuration ID config_10_1
Data Type INTEGER
Range 1 to 100
Default Value 50

1: Group 1

Unsolicited notifications about thermostat mode and setpoint temperature changes

Property Value
Configuration ID group_1
Data Type TEXT
Range to