ZME_KFOB-S Secure 4 Button Key Chain Controller
This describes the Z-Wave device ZME_KFOB-S, manufactured by Z-Wave.Me with the thing type UID of zwaveme_zmekfobs_00_000
.
Secure 4 Button Key Chain Controller
Channels
The following table summarises the channels available for the ZME_KFOB-S Secure 4 Button Key Chain Controller.
Channel | Channel Id | Channel Type UID | Category | Item Type |
---|---|---|---|---|
Scene Number | scene_number | scene_number | Number | |
battery-level | system.battery-level |
Device Configuration
The following table provides a summary of the configuration parameters available in the ZME_KFOB-S Secure 4 Button Key Chain Controller. Detailed information on each parameter can be found below.
Parameter | Description |
---|---|
1: Button 1 and 3 pair mode | Set Button 1 and 3 pair mode |
2: Button 2 and 4 pair mode | Set Button 2 and 4 pair mode |
11: Command to Control Group A | Set Command to Control Group A |
12: Command to Control Group B | Set Command to Control Group B |
13: Command to Control Group C | Set Command to Control Group C |
14: Command to Control Group D | Set Command to Control Group D |
21: Send the following Switch All commands | Set Send the following Switch All commands |
22: Invert buttons | Invert buttons |
25: Blocks wakeup even when wakeup interval is set | Set Blocks wakeup even when wakeup interval is set |
30: Send unsolicited Battery Report on Wake Up | Set Send unsolicited Battery Report on Wake Up |
1: Lifeline | |
2: Control Group A | |
3: Control Group B | |
4: Control Group C | |
5: Control Group D |
1: Button 1 and 3 pair mode
Set Button 1 and 3 pair mode
Overview
In separate mode button 1 works with group A, button 3 with groups C. Click is On, Hold is dimming Up, Double click is Off, Click-Hold is dimming Down. In pair button 1/3 are Up/Down correspondingly. Click is On/Off, Hold is dimming Up/Down. Single clicks works with group A, double click with group C. Default Value: 01
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_1_1 | |||
Data Type | INTEGER | Default Value | 1 | |
Options | Separately (0) | |||
In pair without double clicks (1) | ||||
In pair with double clicks (2) |
2: Button 2 and 4 pair mode
Set Button 2 and 4 pair mode
Overview
In separate mode button 2 works with control group B, button 4 with control group D. Click is On, Hold is dimming Up, Double click is Off, Click-Hold is dimming Down. In pair button B/D are Up/Down correspondingly. Click is On/Off, Hold is dimming Up/Down. Single clicks works with group B, double click with group D. Default Value: 01
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_2_1 | |||
Data Type | INTEGER | Default Value | 1 | |
Options | Separately (0) | |||
In pair without double clicks (1) | ||||
In pair with double clicks (2) |
11: Command to Control Group A
Set Command to Control Group A
Overview
This parameter defines the command to be sent to devices of control group A when the related button is pressed. Default Value: 08
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_11_1 | |||
Data Type | INTEGER | Default Value | 8 | |
Options | Disabled (0) | |||
Switch On/Off and Dim (send Basic Set and Switch Multilevel) (1) | ||||
Switch On/Off only (send Basic Set) (2) | ||||
Switch All (3) | ||||
Send Scenes (4) | ||||
Send Preconfigured Scenes (5) | ||||
Control devices in proximity (6) | ||||
Control DoorLock (7) | ||||
Central Scene to Gateway (8) |
12: Command to Control Group B
Set Command to Control Group B
Overview
This parameter defines the command to be sent to devices of control group B when the related button is pressed. Default Value: 08
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_12_1 | |||
Data Type | INTEGER | Default Value | 8 | |
Options | Disabled (0) | |||
Switch On/Off and Dim (send Basic Set and Switch Multilevel) (1) | ||||
Switch On/Off only (send Basic Set) (2) | ||||
Switch All (3) | ||||
Send Scenes (4) | ||||
Send Preconfigured Scenes (5) | ||||
Control devices in proximity (6) | ||||
Control DoorLock (7) | ||||
Central Scene to Gateway (8) |
13: Command to Control Group C
Set Command to Control Group C
Overview
This parameter defines the command to be sent to devices of control group C when the related button is pressed. Default Value: 08
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_13_1 | |||
Data Type | INTEGER | Default Value | 8 | |
Options | Disabled (0) | |||
Switch On/Off and Dim (send Basic Set and Switch Multilevel) (1) | ||||
Switch On/Off only (send Basic Set) (2) | ||||
Switch All (3) | ||||
Send Scenes (4) | ||||
Send Preconfigured Scenes (5) | ||||
Control devices in proximity (6) | ||||
Control DoorLock (7) | ||||
Central Scene to Gateway (8) |
14: Command to Control Group D
Set Command to Control Group D
Overview
This parameter defines the command to be sent to devices of control group D when the related button is pressed. Default Value: 08
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_14_1 | |||
Data Type | INTEGER | Default Value | 8 | |
Options | Disabled (0) | |||
Switch On/Off and Dim (send Basic Set and Switch Multilevel) (1) | ||||
Switch On/Off only (send Basic Set) (2) | ||||
Switch All (3) | ||||
Send Scenes (4) | ||||
Send Preconfigured Scenes (5) | ||||
Control devices in proximity (6) | ||||
Control DoorLock (7) | ||||
Central Scene to Gateway (8) |
21: Send the following Switch All commands
Set Send the following Switch All commands
Overview
Send the following Switch All commands
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_21_1 | |||
Data Type | INTEGER | Default Value | 1 | |
Options | Switch off only (1) | |||
Switch on only (2) | ||||
Switch all on and off (255) |
22: Invert buttons
Invert buttons
Overview
Invert buttons
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_22_1 | |||
Data Type | INTEGER | Default Value | 0 | |
Options | No (0) | |||
Yes (1) |
25: Blocks wakeup even when wakeup interval is set
Set Blocks wakeup even when wakeup interval is set
Overview
If the KFOB wakes up and there is no controller nearby, several unsuccessful communication attempts will drain battery
Size: 1 Byte, Default Value: 00
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_25_1 | |||
Data Type | INTEGER | Default Value | 0 | |
Options | Wakeup is blocked (0) | |||
Wakeup is possible if configured accordingly (1) |
30: Send unsolicited Battery Report on Wake Up
Set Send unsolicited Battery Report on Wake Up
Overview
Set Send unsolicited Battery Report on Wake Up
Property | Value | |||
---|---|---|---|---|
Configuration ID | config_30_1 | |||
Data Type | INTEGER | Default Value | 1 | |
Options | No (0) | |||
To same node as wake up notification (1) | ||||
Broadcast to neighbors (2) |
1: Lifeline
Property | Value |
---|---|
Configuration ID | group_1 |
Data Type | TEXT |
Range | to |
2: Control Group A
Overview
Control Group A, controlled by button 1 or single clicks of buttons
Property | Value |
---|---|
Configuration ID | group_2 |
Data Type | TEXT |
Range | to |
3: Control Group B
Overview
Control Group B, controlled by button 2 or single clicks of buttons 2
Property | Value |
---|---|
Configuration ID | group_3 |
Data Type | TEXT |
Range | to |
4: Control Group C
Overview
Control Group C, controlled by button 3 or double clicks of buttons 1
Property | Value |
---|---|
Configuration ID | group_4 |
Data Type | TEXT |
Range | to |
5: Control Group D
Overview
Control Group D, controlled by button 4 or double clicks of buttons 2
Property | Value |
---|---|
Configuration ID | group_5 |
Data Type | TEXT |
Range | to |
Did you spot an error in the above definition or want to improve the content? You can edit the database here.