Z-Weather Z-Wave weather interface

This describes the Z-Wave device Z-Weather, manufactured by Z-Wave.Me with the thing type UID of zwaveme_zweather_00_000.

Z-Wave weather interface

Channels

The following table summarises the channels available for the Z-Weather Z-Wave weather interface.

Channel Channel Id Channel Type UID Category Item Type
Binary Sensor sensor_binary sensor_binary Door Switch
Sensor (luminance) sensor_luminance sensor_luminance Temperature Number
Sensor (velocity) sensor_velocity sensor_velocity   Number
Sensor (barometric pressure) sensor_barpressure sensor_barpressure Temperature Number
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number
Sensor (relative humidity) sensor_relhumidity sensor_relhumidity Humidity Number
Sensor (dew point) sensor_dewpoint sensor_dewpoint Temperature Number
Electric meter (pulses) meter_pulse meter_pulse Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
  battery-level system.battery-level    

Sensor (temperature)

Scale

Select the scale for temperature readings

Property Value      
Configuration ID config_scale      
Data Type TEXT   Default Value 0
Options Celsius (0)      
  Fahrenheit (1)      

Device Configuration

The following table provides a summary of the configuration parameters available in the Z-Weather Z-Wave weather interface. Detailed information on each parameter can be found below.

Parameter Description
1: Wind Speed Action Threshold Available Parameters: 0 - Off 1 - 30 in milliseconds Default = 6 m/s
2: Twilight Action Threshold Set from 0 - 100 % Default = 37% (street lighting)
1: Life Line  
2: Wind Speed Wind speed is higher than 6 m/s (22 Km/h)
3: End of Dawn At the end of the dawn if it becomes bright
4: End of Dusk At the end of the dusk if it becomes bright

1: Wind Speed Action Threshold

Available Parameters: 0 - Off 1 - 30 in milliseconds Default = 6 m/s

Property Value
Configuration ID config_1_1
Data Type INTEGER
Range 0 to 30
Default Value 6

2: Twilight Action Threshold

Set from 0 - 100 % Default = 37% (street lighting)

Property Value
Configuration ID config_2_1
Data Type INTEGER
Range 0 to 100
Default Value 37

1: Life Line

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Wind Speed

Wind speed is higher than 6 m/s (22 Km/h)

Property Value
Configuration ID group_2
Data Type TEXT
Range to

3: End of Dawn

At the end of the dawn if it becomes bright

Property Value
Configuration ID group_3
Data Type TEXT
Range to

4: End of Dusk

At the end of the dusk if it becomes bright

Property Value
Configuration ID group_4
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.