ST812 Flood sensor

This describes the Z-Wave device ST812, manufactured by ZyXEL with the thing type UID of zyxel_st812_00_000.

Flood sensor

Channels

The following table summarises the channels available for the ST812 Flood sensor.

Channel Channel Id Channel Type UID Category Item Type
  battery-level system.battery-level    
Alarm (flood) alarm_flood alarm_flood Door Switch

Device Configuration

The following table provides a summary of the configuration parameters available in the ST812 Flood sensor. Detailed information on each parameter can be found below.

Parameter Description
1: Basic Level Set The value sent with Basic commands in case of detected flood
1: Power applied and Sensor Alarm  
2: Device control Group to send trigger value to

1: Basic Level Set

The value sent with Basic commands in case of detected flood

Overview

0 = Off

1-99 = On (Binary Switch Device),  Dim Level (Multilevel Switch Device)

Property Value      
Configuration ID config_1_1      
Data Type INTEGER      
Range 0 to 99   Default Value 99
Options OFF (0)      

1: Power applied and Sensor Alarm

Overview

The Detector will send ALARM_REPORT command to the nodes of Group 1 to inform the devices that the Detector is powered up.

ALARM_REPORT Command: [Command Class Alarm, Alarm Type = 0x02, Alarm Level = 0x01]

The second type for Group 1 is SENSOR_ALARM_REPORT.  255 = Alarm, 00 = Event clear.

The third type for Group 1 is ALARM_REPORT type 0x01, Low battery

Property Value
Configuration ID group_1
Data Type TEXT
Range to

2: Device control

Group to send trigger value to

Overview

Will send values of 0-99 to devices in Group 2.  Set the value to send in Parameter 1.

Property Value
Configuration ID group_2
Data Type TEXT
Range to

Did you spot an error in the above definition or want to improve the content? You can edit the database here.